0
DRIVE
• Low friction screw drive (linear actuator) rated for -5 ºF to +60 ºF (-2 ºC to +7 ºC).
• Powered by a 2 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm.
• Maximum opening arc of 0º. Approximate opening time (90º): From 5 seconds, depending on weight of gate.
• Generates 330 ft lbs of torque at 2v.
POWER
• The system is powered by a 2 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
• Battery charge is maintained by a 20 Vac, 8 Vac output transformer rectified to 4.5 Vdc (40 VA) through the GTO
control board. One () blade-style control board fuse rated for 5 A.
NOTE: The transformer should not be
directly
connected to any battery. Do not replace fuses
with higher ampere rated fuses; doing so will void your warranty and may damage your control board.
• Battery charge is maintained by
GTO Solar Panel Charger: float voltage of 4.5 Vdc output from solar panel. A gated
diode on the control board prevents battery discharge.
CONTROL
•
GTO
microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be adjusted to
accommodate an optional kit for push-to-open gates (
see Accessory Catalog
).
• Control board has temperature compensated circuits.
• A circuit on the control board regulates charging. "Sleep draw" is 5 mA; "active draw" is 2 to 5 A.
• Auto-memorization of digital transmitter code.
•
GTO remote-mounted RF receiver tuned to 38 MHz.
• Operator length with push-pull tube fully retracted is 33
¾
", mounting point to mounting point. Max stroke is 3".
• Adjustable auto-close timer and obstruction sensitivity.
• Power terminal bock accommodates a transformer or solar panels.
• DIP switches simplify setup of gate opener.
• Accessory terminal lock is fully compatible with push button controls, digital keypads, safety loops, etc.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if the unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/PRO® 2002XL Auto-
matic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and
condition of gate and installation.
GTO/PRO® 2002XL AUTOMATIC GATE OPERATOR
Technical Specifications
These specifications are subject to change without notice.
IMPORTANT: BALL BEAR-
ING HINGES SHOULD
BE USED ON ALL GATES
WEIGHING OVER 250 Lbs.
NOTE:
"NR" indicates this
size and weight combination
is not recommended for the
GTO/PRO 2002XL.
To determine the number of cycles the gate opener will perform using solar panels, please see the specifications
listed on
page 21
or call
(800) 543-1236
or
(850) 575-4144
for more information.
* An operation cycle is one full opening and closing of the gate.
Number of Cycles Per Day
GTO/PRO 2002XL Gate Capacity /Cycle Chart
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.
Gate W
eight
Gate Length
400 lbs.
300 lbs.
200 lbs.
150 lbs.
100 lbs.
50 lbs.
73
78
83
88
93
5’ - 6’
68
63
58
53
68
73
78
83
88
8’
63
68
73
78
83
10’
58
63
68
73
78
12’