background image

x

 

 

rev 12.14.15

Technical Specifications

DRIVE

• Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-20 ºC to +71 ºC). 

• Powered by a 12 V motor with integral gear reducer.  Motor speed reduced to 260 rpm.

• Maximum opening arc of 110º.  Approximate  opening time (90º): 18 seconds, depending on weight of gate.

POWER

• The system is powered by a 12 Vdc automotive or marine battery. 

• Battery charge is maintained by GTO transformer or optional GTO Solar Panels.  

 IMPORTANT: Never use both transformer and solar panel - this will damage the battery and control board.

• One (1) blade-style fuse is rated for 15 A.

  

  NOTE: The transformer should not be directly connected to any battery.  Do not replace fuses with higher ampere rated  

 

fuses; doing so will void your warranty and may damage your control board.

CONTROL

•  GTO microprocessor-based control board for single leaf, pull-to-open gate installations.

• A circuit on the control board regulates charging.  "Sleep draw" is 15 mA; "active draw" is 2 to 5 A.

• Auto-memorization of digital transmitter code.  

•  GTO RF receiver tuned to 318 MHz. 

• Opener length with push-pull tube fully retracted is 26

3

/

8

", mounting point to mounting point. Maximum

  stroke is 13".

• Adjustable auto-close timer (OFF, 3 to 120 seconds), and obstruction sensitivity.

• Power terminal block accommodates a transformer or solar panels.

• Accessory terminal block fully compatible with all Mighty Mule access controls.

• Control board allows connection of safety edge sensors and photoelectric sensors.

• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.

OPERATIONAL CAPACITY

• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the Mighty Mule 200 Automatic Gate Opener 

when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.

Mighty Mule 200 Gate Opener

* These specifications are subject

   to change without notice.

Gate W

eight

Gate Length

Number of Cycles Per Day

Mighty Mule 200 Gate Capacity /Cycle Chart 

Estimated number of daily cycles, based on use with a transformer.

300 lbs.
150 lbs.
100 lbs.

50 lbs.

77
82
87
92

5’ - 6’

72
77
82
87

8’

67
72
77
82

10’

62
67
72
77

12’

 

NOTE:

  BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.

  To determine the number of cycles the gate opener will perform using solar panels, please see the specifications listed on page xi.

 

  * An operation cycle is one full opening and closing of the gate.

Содержание Mighty Mule FM200

Страница 1: ...or more information on Mighty Mule s full line of Automatic Gate Openers and Access Controls visit www mightymule com 1 3 BU F N BZ N PWF BU BOZ U J N F P OPU BM M PX DIJ M ES FO U P PQFS BU F HBU F P...

Страница 2: ...ener This gate opener produces a high level of force Stay clear of the unit while it is operating and exercise caution at all times All automatic gate openers are intended for use on vehicular gates o...

Страница 3: ...Items Not Included xiv GATE OPERATOR INSTALLATION 1 CLOSED POSITION STOP PLATE INSTALLATION 3 CONTROL BOX AND BATTERY INSTALLATION 4 TRANSFORMER WIRING INSTALLATION 5 SOLAR PANEL INSTALLATION 6 SETTIN...

Страница 4: ...Mule Gate Opener features adjustable obstruction sensing This safety feature makes the gate stop and reverse direction within 2 seconds when it comes in contact with an obstruction MIN is the factory...

Страница 5: ...disconnected be completely exhaustive in nature They do however provide an overview of the safe design installation and use of this product CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS WARNINGS AN...

Страница 6: ...Make sure the gate has been properly installed and swings freely in both directions Repair or replace all worn or damaged gate hardware prior to installation A freely moving gate will require less fo...

Страница 7: ...ere a user will be tempted to reach through the gate to activate the gate opener 5 Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people p...

Страница 8: ...nges Apply silicone spray to a soft dry cloth and clean the push pull tube at least once a month 7 To operate this equipment safely YOU must know how to disconnect the operator for manual gate operati...

Страница 9: ...te operator for entrapment protection functions shall be located where the transmission of the signals is not obstructed or impeded by building structures natural landscaping or similar obstruction A...

Страница 10: ...te We recommend using a Pedestrian Gate Lock Call the GTO Sales Department at 800 543 4283 for controlled access Required Safety Precautions for Gates Install Warning Signs IMPORTANT SAFETY INFORMATIO...

Страница 11: ...283 for free replacements Logo and warning labels 2 installed on each side of opener housing Control box label 1 installed on front of control box If any of these signs or warning decals become damage...

Страница 12: ...point to mounting point Maximum stroke is 13 Adjustable auto close timer OFF 3 to 120 seconds and obstruction sensitivity Power terminal block accommodates a transformer or solar panels Accessory ter...

Страница 13: ...charging power to charge the battery FM121 Refer to the Solar Panel and Gate Activity chart below All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor stranded direct b...

Страница 14: ...he operator is activated Make sure there is a stable area for mounting the gate bracket this may require the addition of a horizontal or vertical cross member We recommend you position the operator ne...

Страница 15: ...Lock Nut 1 Hairpin Clip 2 2 Mounting Screw 3 1 K E E P C L E A R G a t e m a y m o v e a t a n y t i m e 2 D o n o t a l l o w c h i l d r e n t o o p e r a t e g a t e o r p l a y i n g a t e a r e a...

Страница 16: ...uit If your gate is more than 1000 away from an ac power source you will need to use at least one Mighty Mule 5 watt solar panel to trickle charge the battery See the accessory catalog Do not use both...

Страница 17: ...t any tim e 2 Do not allo w chil dre n to ope rate gat e or pla y in gat e are a 3 Thi s gat e is for veh icle s onl y Ped estr ian s mu st use a sep ara te ent ran ce Moving Gate Can Cause Injury Or...

Страница 18: ...te cross support Attach post bracket assembly to fence post NOTE Must be through bolted GATE OPERATOR INSTALLATION 1 3 5 11 1 KEE P CLE AR Gat e ma y mo ve at any tim e 2 Do not allo w chil dre n to o...

Страница 19: ...st use a sep ara te ent ran ce Moving Gate Can Cause Injury Or Death WARNIN G 15 4 J 1 2 1 1 2 Attach and secure opener assembly to brackets Attach gate bracket assembly to gate cross support Check fo...

Страница 20: ...may move at any time 2 Do not allow child ren to opera te gate or play in gate area 3 This gate is for vehic les only Pede strian s must use a sepa rate entra nce Mo vin g Ga te Can Cause Injury Or De...

Страница 21: ...S E TIM E MIN MA X STALL FO RC E 3 POWER OFF 120 AUTO CLOSE TIME MIN MAX STALL FORCE ON OFF SG1 ED1 K1 06 AVR ISP D1 C2 C7 C15 LED3 D15 R20 IC4 D16 D13 D14 K2 BATT BATT STATUS ANT SHLD S9 8874 EDGE CO...

Страница 22: ...F1 VAR6 WHT GTO Inc Tallahassee FL CYCLE EXIT SAFETY COM CHGR CHGR Correct Wrong Wrong Wire Screwedinto wireinsulation Exposedstrands ofwire 5 POWER ON OFF SG1 ED1 K1 06 AVR ISP D1 C2 C7 C15 LED3 D15...

Страница 23: ...transmitters are set to a standard code at the factory and are ready to operate your gate opener For your safety and security however we strongly recommend that you replace the factory setting with yo...

Страница 24: ...need to increase the stall force See page 9 1 POWER ON OFF SG1 ED1 K1 06 AVR ISP D1 C2 C7 C15 LED3 D15 R20 IC4 D16 D13 D14 K2 BATT BATT STATUS ANT SHLD S9 8874 EDGE COM LOCK LOCK PGOK200 Rev XC M_BLK...

Страница 25: ...K1 06 AVR ISP D1 C2 C7 C15 LED3 D15 R20 IC4 D16 D13 D14 K2 BATT BATT STATUS ANT SHLD S9 8874 EDGE COM LOCK LOCK PGOK200 Rev XC M_BLK M_RED VAR2 GRN VAR3 VAR3 VAR 1 VAR4 VAR5 PF1 VAR6 WH T GTO Inc Tal...

Страница 26: ...compatible products for your specific application Make sure the power to the opener is turned off before connecting safety device wiring to the terminal blocks Unplugging the transformer does not turn...

Страница 27: ...input while at open limit will restart the auto close time if enabled 6 CYCLE Typically for use with doorbell button or hardwired keypad Each activation at this input will cycle the operation as follo...

Страница 28: ...efer to Vehicle Sensor manual for additional information if needed Edge Sensor GTO Lock NOTE Connections are for typical applications For additional connection options not illustrated here refer to th...

Страница 29: ...Path of Gate Gate for Level and Plumb Stall Force Adjustment Disconnect Safety Devices 1 beep with 20 seconds off Low Battery Condition Transformer or Solar Panel Voltage Battery Harness Connections...

Страница 30: ...Power Present Normal Operation Power green OFF No AC or Solar Power Transformer Breaker or GFI Power at AC outlet Output of Transformer Voltage on wire at 18 VAC Input Solar Solar Panel Wires Reversed...

Страница 31: ...on the outside of the package in LARGE BOLD PRINT Ship the package s freight prepaid to GTO Access Systems LLC 3121 Hartsfield Road Tallahassee Florida USA 32303 If your Mighty Mule Gate Opener is no...

Страница 32: ...Find Symbol centimeters 0 3937 inches in or meters 3 2808 feet ft or kilograms 2 2046 pounds lb or Converting English Units to Metric Equivalents When You Know Multiply By To Find Symbol inches 2 540...

Страница 33: ...Mule entry transmitter with adjustable code settings is standard equipment with all Mighty Mule systems battery is included Digital Keypad FM137 Allow friends access to your property using an identif...

Страница 34: ...9U NB The Garage Door Receiver allows you to use the same 2 button Mighty Mule entry transmitter to operate your gate operator and your garage door operator Compatible with most garage door operators...

Страница 35: ...Notes NOTES...

Страница 36: ...Hartsfield Road Tallahassee Florida USA 32303 Telephone GTO Sales 1 800 543 4283 Fax 850 575 8912 or GTO Technical Service 1 800 543 1236 Fax 850 575 8950 www mightymule com America s 1 D I Y Gate Op...

Отзывы: