Technical Specifications
DRIVE
• Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-20 ºC to +71 ºC).
• Powered by a 12 V motor with integral gear reducer. Motor speed reduced to 260 rpm.
• Maximum opening arc of 110º. Approximate opening time (90º): 18 seconds, depending on weight of gate.
POWER
• The system is powered by a 12 Vdc automotive or marine battery.
• Battery charge is maintained by GTO transformer or optional GTO Solar Panels.
IMPORTANT: Never use both transformer and solar panel - this will damage the battery and control board.
• One (1) blade-style fuse is rated for 15 A.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated
fuses; doing so will void your warranty and may damage your control board.
CONTROL
• GTO microprocessor-based control board for single leaf, pull-to-open gate installations.
• A circuit on the control board regulates charging. "Sleep draw" is 15 mA; "active draw" is 2 to 5 A.
• Auto-memorization of digital transmitter code.
• GTO RF receiver tuned to 318 MHz.
• Opener length with push-pull tube fully retracted is 26
3
/
8
", mounting point to mounting point. Maximum
stroke is 13".
• Adjustable auto-close timer (OFF, 3 to 120 seconds), and obstruction sensitivity.
• Power terminal block accommodates a transformer or solar panels.
• Accessory terminal block fully compatible with all Mighty Mule access controls.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the Mighty Mule 200 Automatic Gate Opener
when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.
Mighty Mule 200 Gate Opener
* These specifications are subject
to change without notice.
Gate W
eight
Gate Length
Number of Cycles Per Day
Mighty Mule 200 Gate Capacity /Cycle Chart
Estimated number of daily cycles, based on use with a transformer.
300 lbs.
150 lbs.
100 lbs.
50 lbs.
77
82
87
92
5’ - 6’
72
77
82
87
8’
67
72
77
82
10’
62
67
72
77
12’
NOTE:
BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate opener will perform using solar panels, please see the specifications listed on page xi.
* An operation cycle is one full opening and closing of the gate.