19
GLENTEK Inc. 208 Standard Street, El Segundo, California 90245, U.S.A. (310) 322-3026
SMA7215 MANUAL
Signal Name
Terminal
Notes
MTR CUR
J1-6
Scale factor: 1V=5A.
LIMIT +
J1-7
Inhibits the motor in the +direction.
LIMIT -
J1-8
Inhibits the motor in the -direction.
CLAMP
J1-9
Brakes the motor and go into inhibit after a period of 100m
seconds.
FAULT
J1-10
Goes low if there is a fault in the amplifier. May be
externally forced low to stop motor rotation in both
directions.
COMMON
J1-11
Common for all signals and shields.
RESET
J1-12
Resets the fault latch. May also be used as an inhibit input.
LS/ECB
J1-13
Goes high if the Low Speed Electronic Circuit Breaker
turns on.
HS/ECB
J1-14
Goes high if the High-Speed Electronic Circuit
Breaker turns on.
OVERVOLT
J1-15
Goes high if the buss voltage rises above 250VDC.
OVERTEMP
J1-16
Goes high if the temperature of the amplifier and motor
rises above the specified temp.
4.3.5
Test Point - J2:
Signal Name
Terminal
Notes
COMMON
J2-1
Common for all signals and shields.
SIG
J2-2
Single-ended signal input.
TACH
J2-3
Tachometer input. Not used in current-mode operation.
DIFF SIG GAIN
J2-4
Differential signal Input gain. NOT USED.
SIG GAIN
J2-5
Single-ended signal Input gain.
TACH GAIN
J2-6
Tachometer feedback gain.
COMP
J2-7
Compensation. Use in conjunction with tachometer gain to
set the system bandwidth.