background image

 

GTD-LYS011764 (CW/WW) User Manual 

 

Control connection

 

The fixture has 5-pin and 3-pin XLR connectors for DMX data input and output as shown below. Connection between the 

console  and  fixture,  and  between fixtures  must  be  made  with 2  core  screened DMX  signal cable.  Maximum connecting 

distance of signal cable is 150 meters. Additional DMX512 signal-amplifier is recommended for longer distance. 

 

Connect the Console’s DMX OUTPUT to the first fixture’s DMX INPUT, then the first fixture’s DMX OUTPUT to the second 

fixture’s DMX INPUT and so on. It is recommended not to connect more than 32 units on a single DMX universe. On the 

last fixture‘s output connect a DMX terminator. (The terminator is a XLR connector with a ¼ W and 120Ω resistor between 
the pin 2 and pin 3) as shown below: 

 

Testing 

Connect the fixture to AC power. Check if the LED lamp is on and the fixture is independently controllable before putting 

into operation. 

Control panel 

 

 

The control panel with buttons and digital display can access the function menu and configure the fixture easily. 

 

Press  MENU  to  check  or  modify  the  functions  of  the  fixture;  Press  UP  or  DOWN  to  view  or  select  the  function 
menu. 

 

Press  ENTER  to  choose  a  function  and  enter  into  corresponding  sub  menu.  Each  menu  represents  a  specific 
function of the fixture. 

Содержание GTD-LYS011764

Страница 1: ...LED Flat Wash GTD LYS011764 CW WW User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Страница 2: ... companies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained ...

Страница 3: ...sories 5 Product introduction 6 Installation 7 Clamps installation 7 Device installation 7 Power Control connection 7 Power connection 7 Control connection 8 Testing 8 Control panel 8 Menu structure 9 DMX protocol 9 Technical specification 9 Cleaning and maintenance 11 Troubleshooting 12 System wiring diagram 13 Spare parts list 14 Appendix 1 14 ...

Страница 4: ...ONLY Do not expose fixture for rain and moisture It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should...

Страница 5: ...re changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for installation operation and maintenance by qualified ...

Страница 6: ... then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along with all the accessories Close the cover Only...

Страница 7: ...al 6 Product introduction 1 Arm bracket 2 Adjustable screw 3 Movable bolt 4 LED lamp 5 Slot for barn door installation 6 Display 7 DMX input 3 pin 5 pin 8 Power input 9 Fuse 10 Power switch 11 DMX output 3 pin 5 pin 12 Power output ...

Страница 8: ... Control connection Power connection Connection method L Live Brown wire E Earth Yellow Green bi color wire N Neutral Blue wire The voltage and frequency of the power source must be in compliance with the ones marked on the fixture Please apply series connection when many sets of fixtures are connected to the power source to avoid heavy load to the power source When the voltage is 110V maximum 4 s...

Страница 9: ...s recommended not to connect more than 32 units on a single DMX universe On the last fixture s output connect a DMX terminator The terminator is a XLR connector with a W and 120Ω resistor between the pin 2 and pin 3 as shown below Testing Connect the fixture to AC power Check if the LED lamp is on and the fixture is independently controllable before putting into operation Control panel The control...

Страница 10: ...isplay Ver V1 0 V9 9 software version DMX protocol Channel Function Value Description 1 Dimmer 0 255 0 100 Technical specification Optical Light source LED 0 1W quantity 1764pcs Expected average lifetime 50000 hours Beam angle fixed 42 50 peak angle 78 10 peak angle Photometric Color temperature 5600K CW 3200K WW CRI 90Ra Electrical Power input nominal AC 100 240W 50 60Hz Max Power consumption 170...

Страница 11: ... movement Manually adjustable Dimmer 0 100 16 bit electronic linear dimming Thermal Operating range 14 F to 113 F 10 C to 45 C Startup range 5 F to 113 F 15 C to 45 C Storage range 40 F to 140 F 40 C to 60 C Cooling Passive Humidity 85 Connections AC power Neutrik powerCon DMX data input output Chassis 5 pin Neutrik XLR in out Certification and Safety EMC EN 55103 1 2009 EN 55103 2 2009 EN 61000 3...

Страница 12: ...ters or housing of the fixture If the lens is cracked or otherwise damaged replace it immediately If the LED lamp becomes damaged or deformed in any way it must be replaced If the light from the LED lamp appears dim this normally indicates that it is reaching the end of its life span and should be changed at once Aged LED lamps run to the extremity of their life might explode If fixture does not f...

Страница 13: ...Mode of the fixture Choose the channel mode in Channel setting Channel Mode of the fixture as required by the user Malfunctioning of DMX cannon input output connectors No input output voltage to the main control board of the fixture Troubleshooting the DMX XLR signal plate of the fixture replace the main control board of the fixture LED lamp off There is no signal output to the main control board ...

Страница 14: ...C GND J8 FG L N Switching power supply E L N GND LJB0525B P3 P2 GND Terminal 1407090002A EDS200 4824 48V 3 6A 24V 1A 5809210025A P4 P5 P1 LCR0012C 5802910060A J1 LCR0012C J1 LCR0012C J1 J5 SKL005A SKL004A 5802910003A 5802910002A 5802910060A 5802910060A 5802910061A 5802910061A 5802910061A GTD LYS011764 ...

Страница 15: ...S01176 101E10 102G10 SDI0014C LED lamp board WW 5802910061A 3 LCR0012C LED lamp board CW 5802910060A 3 LCR0012C XLR board 4 5802910002A 1 SKL0004A XLR board 5 5802910003A 1 SKL0005A LED aluminum substrate 5802010050A 1 LJB0525B Switching power supply 1412050053A 1 EDS200 4824 48V 3 6A 24V 1A Appendix 1 ...

Страница 16: ...GTD LYS011764 CW WW User Manual 15 Notes P N 1502011040A Time August 9th 2017 ...

Отзывы: