instructions for:
LED fLooDLight with brackEt
anD pir sEnsor 20w 230V
MoDEL no:
LED120s
thank you for purchasing a sealey product. Manufactured to a
high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT
:
pLEasE rEaD thEsE instrUctions carEfULLY. notE thE safE opErationaL rEQUirEMEnts, warnings, anD
caUtions. UsE this proDUct corrEctLY, anD with carE for thE pUrposE for which it is intEnDED. faiLUrE to Do so
MaY caUsE DaMagE, or pErsonaL inJUrY, anD wiLL inVaLiDatE thE warrantY.
1. safEtY instrUctions
4. instaLLation instrUctions
2. introDUction
3. spEcification
fig 1.
Original Language Version
LED120s issue: 1 - 20/07/12
specifications:
supply......................................................................................................... 230V.
Power: ......................................................................................................... 20W.
Lumen output ...........................................................................................1200lm
Detection Angle: ..................................................................... 120° (fan shape).
Detection range: ..................................................................... 12m (Adjustable).
time Delay: .............................................6 seconds to 20 minutes (Adjustable).
Light sensitivity: .................................................................. 30 Lux (Adjustable).
1.1. ELEctricaL.
warning!
it is the user’s responsibility to read, understand and
comply with the following:
warning! this proDUct MUst bE instaLLED bY a QUaLifiED
ELEctrician.
You must check all electrical equipment and appliances to ensure they
are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear and damage. You must ensure the risk
of electric shock is minimised by the installation of appropriate safety
devices. An rccB (residual current circuit Breaker) should be
incorporated in the main distribution board.
You must
also read and
understand the following instructions concerning electrical safety.
1.1.1. Ensure the light is connected to an appropriate electrical on/off switch.
1.1.2. Ensure the insulation on all cables and the product itself is safe before
connecting to the mains power supply.
1.1.3. Ensure that cables are always protected against short circuit and
overload.
1.1.4. regularly inspect power supply, leads, plugs and all electrical
connections for wear and damage, especially power connections, to
ensure that none are loose.
1.1.5.
Important:
Ensure the voltage marked on the product is the same as
the electrical power supply to be used.
1.1.6.
Do not
pull power cable once installed.
1.1.7.
Do not
pull power plugs from sockets by the power cable.
1.1.8.
Do not
use worn or damaged leads, plugs or connections.
immediately replace or have repaired by a qualified Electrician.
1.1.9
Ensure the unit is correctly earthed and wired according
to fig.1 to the right.
Slide the gland nut and silicon cable seal over the cable
before inserting it through the cable entry point in the
base of the rear cover. Pass the cable through the cable
clamp before wiring up as follows:
a) Connect the gREEN/YEllOw earth wire to the earth
terminal ‘E’.
b) Connect the bROwN live wire to live terminal ‘l’.
c) Connect the bluE neutral wire to the neutral terminal ‘N’.
After wiring, check there are no bare wires, that all wires
have been correctly connected and that the cable clamp
and cable entry gland nut are tight.
1.2. gEnEraL safEtY.
warning! turn off the mains power supply before servicing or
performing any maintenance.
Maintain the light in good condition (repairs must only be undertaken
by a qualified electrician).
replace or repair damaged parts. use genuine parts only, non
authorised parts may be dangerous and will invalidate the warranty.
Ensure the light is installed correctly in accordance with these
instructions.
only install the light on a vertical surface.
Do not
fix the light on any
horizontal surface i.e. ceiling, or overhang.
ideally the installation should be away from flammable or combustible
materials such as wood, cloth, paper etc.
DangEr! Do not direct the light into a persons eyes. this unit
has a very intensive light output, which if incorrectly used could
cause eye damage.
Do not
install the light where it is likely to be knocked or hit.
Do not
install in bathrooms, shower rooms, sauna or such locations.
Do not
install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc.
Do not
touch the light when operating, allow to cool before touching,
light operates at high temperature.
Do not
use the light without the front glass shield. Avoid touching the
glass shield as handling may reduce its serviceable life and cause the
glass to crack.
Do not
use the light near flammable, combustible or explosive
liquids, solids, gases or equipment.
Motion detector unit automatically switches on when approached by vehicles or
people. Mounted in die-cast powder coated aluminium housing with wall
bracket. state of the art LED chip technology allows ultra bright illumination
whilst still keeping costs lower than traditional halogen bulbs. Even spread of
light across a 120° angle. fitted with adjustable sensitivity and light duration
controls. supplied without mains cable and suitable for outdoor mounting.
warning! Do not
connect unit to the mains power supply before
installation. When ready, the lamp must only be connected to the mains
by a qualified electrician.
4.1. fitting
Give careful consideration to the position of unit to ensure you obtain
maximum benefit from the lighting range, and that an appropriate
electrical power source can be provided.
4.1.1
Do not
install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc
as variance in temperature will effect the sensitivity of light. the light
must be mounted on a vertical surface only i.e. on a wall etc.
Do not
mount on a horizontal surface i.e. ceiling or an overhang,
Do not
mount so that the face of the lamp is pointing upwards, or is
facing towards the mounting surface. An approximate appropriate
mounting height from the ground is 2.5m.
4.1.2 this LED floodlight develops minimal heat and is not subject to the
same mounting restrictions that apply to halogen lamps that become too
hot to touch. We do however recommend that the floodlight should not
be placed in cramped or restrictive positions and should be fixed at the
© Jack sealey Limited