GSW 72090 Скачать руководство пользователя страница 6

III) INSTALLATION

Unpacking the Water Heater

Important:

Do not remove any permanent instructions,

labels or the rating plate from the outside of the water heater
or on the inside of panels.

1. Move the water heater to the location of installation

before removing the exterior packaging.

2. Remove exterior packaging and place installation com-

ponents aside.

3. Inspect all parts for damage prior to installation and

start-up.

4. Completely read and understand all instructions before

attempting to assemble and install this product.

If you observe damage to the water heater or any of its com-
ponents, DO NOT ASSEMBLE OR INSTALL IT OR MAKE
ANY ATTEMPT TO FIX THE DAMAGED PART(S). Contact
the place of purchase for further instructions.
5. After installation, dispose of packaging material in the

proper manner.

Location Requirements

Note:

Before installing this water heater, consideration and

planning must be given to the following details:

Location and Clearances.

Access for gas supply; See “Gas Supply”.

How and where to obtain combustion and ventilation air
supply; See “Air Requirements”.

Routing and support of the vent piping.

Position of water supply and placement of water piping
for hot and cold water; See “Water Supply”.

Floor drain and service.

In Earthquake Zones

Note:

The water heater must be braced, anchored, or

strapped to avoid moving during an earthquake. Contact
local utilities for code requirements in your area.

Note:

REVIEW SAFETY WARNINGS FOUND IN THE

FRONT OF THIS MANUAL BEFORE PROCEEDING

Clearances and Accessibility

Specific clearance locations are shown in Figure 3. A mini-
mum of 600mm (24 in.) of front clearance shall be provided
for inspection and service. We recommend that 0.9m (36
in.) above be maintained for serviceability.

Locate the water heater such that all controls are easily
accessible.

Clearance to combustibles varies by model.  Refer to rating
plate to confirm clearances.
Heaters with a volume of 19 gallons through 50 gallons and
60 gallon (standard input) must have the following minimum
clearances to combustibles:

Front

102mm (4 in.)

Sides and Rear

25mm (1 in.)

Top

203mm (8 in.)

Flue

152mm (6 in.)

JW6058 and G6058 (high input) series heaters must have
the following minimum clearances to combustibles:

Front

127mm (5 in.)

Sides and Rear

25mm (1 in.)

Top

203mm (8 in.)

Flue

152mm (6 in.)

WARNING

Excessive Weight Hazard

Use two or more people to move and install
water heater. Failure to do so can result in
back or other injury.

IMPORTANT:

This water heater must be installed strictly in accordance
with the instructions enclosed, and local electrical, fuel
and building codes. It is possible that connections to the
water heater, or the water heater itself, may develop
leaks. IT IS THEREFORE IMPERATIVE that the water
heater be installed so that any leakage of the tank or relat-
ed water piping is directed to an adequate drain in such a
manner that it cannot damage the building, furniture, floor
covering, adjacent areas, lower floors of the structure or
other property subject to water damage. This is particular-
ly important if the water heater is installed in a multi-story
building, on finished flooring or carpeted surfaces. GSW
WILL NOT ASSUME ANY LIABILITY for damage caused
by water leaking from the water heater, pressure relief
valve, or related fittings. Select a location as centralized
within the piping system as possible. In any location
selected, it is recommended that a suitable drain pan be
installed under the water heater. This pan must limit the
water level to a MAXIMUM depth of 45mm (1 3/4 in.) and
have a diameter that is a minimum of 50mm (2 in.) greater
than the diameter of the water heater. Suitable piping shall
connect the drain pan to a properly operating floor drain.
When used with a fuel-fired heater, this drain pan must not
restrict combustion air flow.

45mm

(1 3/4 in.)

MAX

AT LEAST 50mm (2 in.)

GREATER THAN THE

DIAMETER OF THE

WATER HEATER.

PIPE TO

ADEQUATE

DRAIN

Figure 1

Typical Drain Pan Installation

– 6 –

Содержание 72090

Страница 1: ...her flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified installer service agency or the gas utility Do not try to li...

Страница 2: ...2 This page intentionally left blank May be used for notes or to record other installation information...

Страница 3: ...ermal Expansion Temperature and Pressure T P Relief Valve 12 The Temperature And Pressure Relief Valve The Discharge Line Installations Check 13 IV OPERATING INSTRUCTIONS 14 Water Temperature Regulati...

Страница 4: ...ition to the installation instructions found in this man ual the heater shall be installed according to all local and provincial or state codes or in the absence of such codes with the latest edition...

Страница 5: ...hut Off Devices for Hot Water Supply Systems ANSI Z21 22 is applicable If this water heater has been exposed to flooding freezing fire or any unusual condition do not put it into operation until it ha...

Страница 6: ...plate to confirm clearances Heaters with a volume of 19 gallons through 50 gallons and 60 gallon standard input must have the following minimum clearances to combustibles Front 102mm 4 in Sides and Re...

Страница 7: ...ation a leaking tank or piping connections Refer to Figure 1 Under no circumstances is the manufacturer to be held responsi ble for any water damage in connection with this water heater Gas Supply Ins...

Страница 8: ...l sources of ignition are de activated Contact your local gas authority for local requirements Gas Leak Testing Important This water heater and its gas connection must be tested for leaks before placi...

Страница 9: ...Refer to Figure 5 a or b and Table 1 for proper sizing and location of combustion air ducts and openings CHECK LOCAL CODES a Two permanent openings shall be provided connecting the confined space e g...

Страница 10: ...Equipment located in confined spaces all air from outdoors When supplying air directly from the outdoors using hor izontal ducting each opening shall have a free mini mum area of one square inch per 2...

Страница 11: ...be installed according to the installation drawing Figure 10 If the indoor installation area is subject to freezing temperatures the water piping must be protected by insulation Water supply pressure...

Страница 12: ...small quantities of hot water To prevent this from happening there are two recommendations 1 Install a diaphragm type expansion tank that is suitable for potable water on the cold water supply line Th...

Страница 13: ...ected to the correct gas supply as shown on the rating plate Natural Gas Propane 6 Is the clearance between the water heater and combustible construction as per specifica tions 7 Is the water piping c...

Страница 14: ...the point of use to exceed the ther mostat setting by up to 17 C 30 F If you experience this type of use you should consider using lower temperature settings to reduce scald hazards Should overheatin...

Страница 15: ...outer door 3 Turnthetemperaturedialcounterclockwise toitslow est setting 4 Turn gas control knob clockwise to the OFF position 5 To clear any gas that may have accu mulated wait ten 10 minutes If you...

Страница 16: ...etemperaturedialcounterclockwise toitslow est setting 4 Turn gas control knob clockwise to the OFF position 5 Toclearanygasthatmayhaveaccumulatedwait ten 10 minutes If you then smell gas STOP Follow i...

Страница 17: ...UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur ne pas vous servir des t l phones se trouvant dans le b timent Appelez imm diatement votre fournisseur de gaz depuis...

Страница 18: ...0 minutes at ini tial start up to ensure that heavy condensation is not turning off the water heater Water Heater Sounds During the normal operation of the water heater sounds or noises may be heard T...

Страница 19: ...the tank and restart the heater as directed under Operating Instructions If the water heater is going to be shut down for an extended period the drain valve should be left open Important Condensation...

Страница 20: ...er 1 Follow first the procedure outlined in External Cleaning of the Flame arrester 2 Remove the outer door and locate the TCO switch on the right side of the combustion chamber door 3 Manually press...

Страница 21: ...as those used for boiler treatment into the potable water used for space heating 3 Do not use this heater as a replacement for an existing boiler installation 4 If the space heating water system requi...

Страница 22: ...hermostat ECO switch open 9 Door mount temperature cut off TCO switch activated 10 Defective igniter or electrode 11 Flammable vapors incident Flame GuardTM function activated 12 Low gas pressure 13 I...

Страница 23: ...ice PROBLEM POSSIBLE CAUSE S CORRECTION INSUFFICIENT HOT WATER 1 Thermostat set too low 2 Sediment or lime in tank 3 Water heater too small 4 Wrong piping connections 5 Leaking faucets 6 Wasted hot wa...

Страница 24: ...0 24 23 21 17 22 24 1 NIPPLE HOT OUTLET 2 NIPPLE COLD INLET 3 DRAFTHOOD 4 TEMPERATURE PRESSURE RELIEF VALVE 5 REDUCER RING 6 ANODE 7 DIP TUBE 8 FLUE BAFFLE 9 DRAIN VALVE 10 BURNER MANIFOLD ASSEMBLY 11...

Страница 25: ...for the defective part s This warranty is limited to one replacement component part for each original part 3 Return of Defective Water Heater and Component Parts Manufacturer reserves the right to ex...

Страница 26: ...rges for labour or other expenses incurred in the removal repair or replacement of the water heater or any component part s claimed to be defective or any expense incurred to remedy any defect in the...

Отзывы: