Содержание GST-FT8WN

Страница 1: ...GST FT8WN Fire Telephone Panel Installation and Operation Manual ...

Страница 2: ...IGN 4 4 1 STAND ALONE FIRE TELEPHONE SYSTEM 4 4 2 NETWORKED FIRE TELEPHONE SYSTEM 5 5 MOUNTING COMMISSION 5 5 1 INITIAL CHECK 5 5 2 WIRING REQUIREMENT 5 5 3 MOUNTING HOLES 6 5 4 TERMINALS ON THE PANEL 6 5 5 SYSTEM COMMISSIONING 7 Set panel address 7 Register the Network Panels 7 Test Functions 7 6 USER GUIDE 8 6 1 CALL HANDSET 8 6 2 CALL TELEPHONE PANEL 8 6 3 CALL TELEPHONE PANELS IN NETWORK 8 6 4...

Страница 3: ...rt circuit and open circuit Panel will show the fault by sound and indicator Failure of one zone will not effect on other zones The network communication is monitored When sub panel fails to communicate with the main panel the main panel will get the failure message and broadcast to other networked sub panels both main panel and sub panels will indicate by sound and light indication When the fault...

Страница 4: ...terminals such as GST FT8WN Handset Field device which can communicate with fire control center such as P 9911 F and P 9911 M Main panel The No 1 panel in the fire telephone panel network Sub panel Panels other than No 1 in the fire telephone panel network 3 Panel Instruction 3 1 Appearance and Structure GST FT8WN fire telephone panel is wall mount type the appearance is shown in Fig 3 1 Fig 3 1 ...

Страница 5: ...g up the corresponding zone 3 4 Indicators Indicator Description Call LED 1 8 Red indicating the conversation status between panel and corresponding zone Flashing in the process of connection On under conversation Off no conversation Ring In LED Red fast flash when there is call in from network or zone Fault LED 1 8 Yellow lit on when corresponding zone in Fault condition Network Fault LED Yellow ...

Страница 6: ...ork the last digit indicates its network address On sub panel only the last digit will show its network address Network Call The first digit indicates the address of the calling panel The C at the last digit means Calling Network Conversation The sample at the left shows the conversation state between No 1 panel and No 2 panel The others will show BUSY Network Failure The first digit indicates the...

Страница 7: ...ission section for setting up addresses Fig 4 2 5 Mounting Commission 5 1 Initial Check Check the appearance of the panel after open the box Then power on and check working state 5 2 Wiring Requirement Cross section area of the power cable not less than 1 5mm2 Twisted pair cable connecting panel and handset with SA not less than 1 0 mm2 Twisted pair cable for the network with SA not less than 1 0 ...

Страница 8: ...ounting holes of the panel Hole distance in the vertical direction 318mm Hole distance in the horizontal direction 218 mm Diameter of the hole 12mm 5 4 Terminals on the panel Fig 5 2 Power 24 GND 24VDC power in polarized E GND Network Network polarized Zn Zn Zone Terminals connecting with handsets a 10KΩ 0 5KΩ resistor is required to the last point of each zone ...

Страница 9: ...work Panels After assigning the addresses power on the sub panels first Press and hold the Network Call button on the main panel and power on The main panel will register all networked sub panels automatically Subsequently the first digit of the digitron will show the number of networked panels including the main panel Check whether all panels have been registered according to the shown number If ...

Страница 10: ...le if there are other zones calling panel Ring In will keep fast flashing Hang up the handset or press the relative key on the panel will stop the conversation 6 3 Call Panels in Network If the handset call is not answered by the panel within 12s and the network is available the call will be transferred to other networked panels Press Network Call and start the conversation Stop the conversation b...

Страница 11: ... an open or short circuit between panel and handsets or the End of Line Resistor not connected Check the cable by multi meter whether the resistance is roughly 10kΩ 7 2 Network Fault The panel shows network fault when there is any of the panels powered off or network cable fault Check the malfunction panel and wiring ...

Страница 12: ...com cn GST UK Global System Technology PLC Lion Court Staunton Harold Hall Melbourne Road Ashby de la Zouch Leicestershire England LE65 1RT Tel 44 1283 225 478 Fax 44 1283 220 690 Email info gst uk com www gst uk com GST Dubai Global System Technology PLC PO Box 17998 Unit ZA04 JEBEL ALI Free Zone Dubai UAE Tel 971 0 4 8833050 Fax 971 0 4 8833053 Email info gst uk com www gst uk com ...