UtilityScan DF Quick Start Guide
Page 14
Filters
(See Appendix C for more information)
•
Stacking (scans): To reduce random or high frequency noise (static or fuzz) in your data. This value should be set
low (3-5). The system will average together that number of scans and output the average value.
•
Background Removal (scans): Remove horizontal banding in your data. This value should be set very high. The
system will remove flat bands in the data of that many scans or higher.
•
Signal Floor: Shows a visual indicator of noise levels. The shaded green area indicates an area of degraded signal in
which some target types (weak reflectors) may not be readily visible.
•
Migration: Allows the computer to estimate a dielectric constant by examining the shape of the hyperbolas.
•
Hilbert Transformation: Change all migrated targets from having a negative and positive polarity to just positive
polarity. Good for giving an idea of the strength of the reflection.
Horizontal Banding Example
Signal Floor Example