- 26 -
PHDQ 8008 TSR
s
tuffing
Bx 4A
SR=6900 (6325)
STUFFING
Number 1 Number 2
SR=6900
(= "Number 1"): Active output symbol rate
(
6325
) (= "Number 2"): Current measured output symbol rate.
—> This value must be less than the value of "Number 1". If necessary
remove stations using the software PSW 1000 or increase the value
of "Number 1".
—> The value fluctuates, since the data rates of individual stations are
dynamically modified by the broadcasters.
—> "Number 2" is not displayed in the channel strips "
A
" or
"
B
" at the settings "
OUTROUTE 1=>ASI ASI=>MA
" or
"
2=>ASI ASI=>MB
", for the symbol rate of the ASI input signal
cannot be measured. The ASI input signal therefore must be built
in such a way so that the output symbol rate set ("Number 1") is
not exceeded.
The symbol rates of the transport streams built by the cassette can be
measured at the setting "
OUTROUTE ASI=>ASI
" and be displayed
in the respective channel strip.
• Use the
buttons to place the cursor under the number to be changed
("Number 1") and set the symbol rate with the buttons
.
The value set corresponds to the new output symbol rate.
Increasing the value of "Number 1".
—> The "Number 1" can be increased to any value up to 7500.
Reducing the value of "Number 1".
—> If the value of "Number 2" is very low compared with "Number 1"
, the "Number 1" can be decreased. To do this, observe the "Number
2" for approx. 30 seconds and note the highest value. Add roughly
10 % to this value. Do not decrease the "Number 1" lower than the
value of "Number 2".
Содержание PHDQ 8008 TSR