background image

 

 

- 3 - 

HAV 470 

s

afety

 

regulations

  •  The standards EN/DIN EN 50083 resp. IEC/EN/DIN EN 60728 must be 

observed.

 

•  Do not perform installation and service work during thunderstorms.

 

•  Assembly,  installation  and  servicing  should  be  carried  out  by  authorised 

electricians.

 

•  Switch off the operating voltage of the system before beginning with assem-

bly or service work.

 

•  Avoid short circuits! 

 

•  Observe the relevant standards, regulations and guidelines on the installa-

tion and operation of antenna systems. 

 

•  To ensure electromagnetic compatibility, make sure all connections are tight 

and the covers are screwed on securely.

 

•  No liability is accepted for damage caused by faulty connections or inap-

propriate handling of the device.

  Check the head-end station

 a

ccording to the safety instructions listed in their 

assembly instruction.

  Take precautions to prevent static discharge when working on the device!

  Electronic devices should never be disposed of in the household rubbish. In 

accordance with directive 2002/96/EC of the European Parliament and the 
European Council from January 27, 2003 which addresses old electronic and 
electrical devices, such devices must be disposed of at a designated collection 
facility. At the end of its service life, please take your device to one of these 
public collection facilities for proper disposal.

Содержание HAV 470

Страница 1: ...ne 49 0 911 703 8877 Fax 49 0 911 703 9210 E mail info gss de Internet http www gss de en HAV 470 Head End Station STC 160 4 x AV Connection Panel Notes on the Assembly Instructions As well as this supplementary Assembly Instructions the Assembly Instructions for the STC 160 apply ...

Страница 2: ...AV socket P1000 5 AV socket P1000 4 x Cinch AV 5 Cinch AV AV socket P2000 AV socket P1000 5 Block diagram 6 3 Installation 6 3 1 Installing the connection panel 7 3 2 Connecting the connection panel 8 Feed in of external AV signals into quadruple modulators 8 Conversion of internal AV signals to ASI or LAN 8 Combination of external and internal signals 9 3 3 EMC regulations 10 4 Final procedures 1...

Страница 3: ...tight and the covers are screwed on securely No liability is accepted for damage caused by faulty connections or inap propriate handling of the device Check the head end station according to the safety instructions listed in their assembly instruction Take precautions to prevent static discharge when working on the device Electronic devices should never be disposed of in the household rubbish In a...

Страница 4: ...g works 2 3 Technical data The devices meet the following EU directives 2006 95 EC 2004 108 EC The product fulfils the guidelines and standards for CE labelling page 12 Unless otherwise noted all values are specified as typical Audio Inputs Impedance 47 kΩ Audio level 0 5 Vrms Eingänge Video Impedance 75 Ω Video level 1 Vpp Anschlüsse CVBS video connectors Cinch 4 Audio connectors Cinch 4 x 2 AV c...

Страница 5: ...ts of the AV socket P2000 can be connected individually to AV socket P1000 Connection variants 4 x Cinch AV AV socket P1000 Feed of external AV signals into the quadruple modulators HFM 470 HMM 470 OIRT HMS 470 OIRT HMS 480 OIRT or HMM 480 OIRT AV socket P1000 4 x Cinch AV Feed of AV signals of the modules HDC 470 CI AV HDC 480 CI AV HDCT 460 AV HDCT 461 AV into the modules HDE 164 or HDC 166 Cinc...

Страница 6: ...nt assembly instructions on the website www gss de en The AV connection panel is designed exclusively for use in the STC 160 head end station 3 Installation Ensure the head end station is mounted so it will not be able to vibrate Avoid for example mounting the head end station onto a lift shaft or any other wall or floor construction that vibrates in a similar way Before installing or changing a m...

Страница 7: ...f the housing Open the housing of the head end station in accordance with the assembly instructions for the STC 160 Open the locking device A in the direction of the green arrow A Insert the connection panel in a shorter groove B between two module slots and gently slide it into the head end station until it locks C After installing the connection panel close the locking device A in the di rection...

Страница 8: ...V signals into quadruple modulators 4 x Cinch AV AV socket P1000 Feed of external AV signals into the quadruple modulators HFM 470 HMM 470 OIRT HMS 470 OIRT HMS 480 OIRT or HMM 480 OIRT Connect the external devices via cinch cables to the cinch sockets of the module Connect AV socket P1000 to the AV socket of a corresponding quadruple modulator Conversion of internal AV signals to ASI or LAN AV so...

Страница 9: ...ia cinch cables to the cinch sockets of the module Connect AV socket P2000 to the AV socket of a corresponding QPSK or COFDM to AV converter Connect AV socket P1000 to the AV socket of a corresponding quadruple modulator Using the DIP switches the desired signals of P2000 can be switched to P1000 Connect only needed contacts Avoid parallel connections of sourc es and sinks Therefore observe the si...

Страница 10: ...terminals When mounting the module in a head end station which is installed in a 19 cabinet make sure the connections leading in and out for the 19 cabinet are made using cable terminals Tighten the nuts on the cable terminals until the teeth on the lock washer have pen etrated the exterior coating and a good connection is made between the housing and cable terminals ...

Страница 11: ...pgrading accessories or installing mod ules it is necessary to tighten all cable connections cable terminals and cover screws in order to maintain compliance with current EMC regulations securely Mount the base plate and the front cover see STC 160 assembly instruc tions ...

Страница 12: ...f CE conformity Alterations reserved Technical data E O E by GSS GmbH 11022013 Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 Email service gss de Grundig SAT Systems GmbH Beuthener Straße 43 D 90471 Nürnberg ...

Отзывы: