GSS GAK 7100 Скачать руководство пользователя страница 7

 

 

- 7 - 

HOC 168

s

etting

 

the

 

output

 

level

 

•  Connect the RF outputs of the modules to the inputs of the RF output collector 

D

 (fig. 5).

 

•  Connect the antenna test receiver to the test output 

C

 of the RF output col-

lector (fig. 5).

 

•  Switch on the head-end station.

 

•  The “Select module / channel strip” – “

SETUP BE160

” menu appears in the 

display. Activate this menu by repeatedly pressing 

 if needed.

Ein/On

SETUP
 

SETUP
Level 

0

OUTPUT

V 10

2 x  M

 

CANCEL

SETUP
 

S => STORE

MEMORY

S

M

/

0 … -31

M

Bx 1A
C5-12,S3-24

TWIN-SAT

C07

Böx 4
C5-12,S3-24

TWIN-SAT

C07

Bx 1A
 

DVBT

C 69

BE160

 

•  Press the   button.

—>  The “Set output level” – “

OUTPUT  Level

” menu is activated. 

 

•  Using the 

 buttons, set the RF output level as required for the cable 

system.

 

•  Press the   button.

—>  The “Store data” – “

MEMORY

” menu is activated. 

 

•  All programmed data is saved by pressing the 

 button. You will be re-

turned to the menu item “Select module / channel strip” – “

SETUP BE160

”.

 

•  By pressing the   button, you will be returned to the menu item “Select 

module / channel strip” – “

SETUP BE160

” 

without

 saving the programmed 

data.

Содержание GAK 7100

Страница 1: ...ssembly Instructions As well as this supplementary Assembly Instructions the Assembly Instructions for the head end station apply GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 Email info gss de Internet www gss de en ...

Страница 2: ...ulations 3 2 General information 3 2 1 Scope of delivery 3 2 2 Meaning of the symbols used 4 2 3 Technical data 4 2 4 Description 4 3 Overview 5 4 Installing the RF output collector 6 5 Setting the output level 7 6 Final procedures 8 ...

Страница 3: ...ility is accepted for damage caused by faulty connections or inap propriate handling of the device Check the head end station according to the safety instructions listed in their assembly instruction Take precautions to prevent static discharge when working on the device Electronic devices should never be disposed of in the household rubbish In accordance with directive 2002 96 EC of the European ...

Страница 4: ...egulator 0 31 dB RF inputs 8 F sockets Input impedance 75 Ω RF output 1 F socket RF test output 20 dB 1 F socket Output impedance 75 Ω 2 4 Description The active RF output collector HOC 168 has 8 RF inputs one RF output and one RF test output 20 dB The RF output collector collects the output signals of the modules modulators and provides them via the output socket for the cable network Via the SET...

Страница 5: ... 5 HOC 168 3 Over view D B A C Fig 1 A Output B Connector block C Test output 20 dB D Inputs ...

Страница 6: ... of the rib bon cable to the backplane E Connect the output cable 1 fig 4 part of the packing con tents of the head end station to the output A of the RF output collector Insert the other end of the out put cable in one of the openings knock outs in the rear panel of the head end station F and tighten it Mount the RF output collector HOC 168 to the position in the head end sta tion according to fi...

Страница 7: ...T V 10 2 x M CANCEL SETUP S STORE MEMORY S M 0 31 M Bx 1A C5 12 S3 24 TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Bx 1A DVBT C 69 BE160 Press the button The Set output level OUTPUT Level menu is activated Using the buttons set the RF output level as required for the cable system Press the button The Store data MEMORY menu is activated All programmed data is saved by pressing the button You will be...

Страница 8: ... and to ensure a reliable operation Securely tighten the cable connections F connector using an open ended spanner spanner width 11 mm 1 2 2 2 Fig 6 Position the breakthroughs in the base plate above the fastening screws 2 fig 6 Push the base plate in direction of the arrow and lock it with the locking screw 1 Tighten the fastening screws 2 Tighten the nuts of retrofitted F terminals if applicable...

Страница 9: ...CE Declaration of Conformity Alterations reserved Technical data E O E by GSS GmbH 28062013 ...

Отзывы: