GSS GAK 7100 Скачать руководство пользователя страница 3

 

 

- 3 - 

HOC 168

s

afety

 

regulations

  •  The standards EN/DIN EN 50083 resp. IEC/EN/DIN EN 60728 must be 

observed.

 

•  Do not perform installation and service work during thunderstorms.

 

•  Assembly,  installation  and  servicing  should  be  carried  out  by  authorised 

electricians.

 

•  Switch off the operating voltage of the system before beginning with assem-

bly or service work.

 

•  Avoid short circuits! 

 

•  Observe the relevant standards, regulations and guidelines on the installa-

tion and operation of antenna systems. 

 

•  To ensure electromagnetic compatibility, make sure all connections are tight 

and the covers are screwed on securely.

 

•  No liability is accepted for damage caused by faulty connections or inap-

propriate handling of the device.

  Check the head-end station

 a

ccording to the safety instructions listed in their 

assembly instruction.

  Take precautions to prevent static discharge when working on the device!

  Electronic devices should never be disposed of in the household rubbish. In 

accordance with directive 2002/96/EC of the European Parliament and the 
European Council from January 27, 2003 which addresses old electronic and 
electrical devices, such devices must be disposed of at a designated collection 
facility. At the end of its service life, please take your device to one of these 
public collection facilities for proper disposal.

g

eneral

 

information

2.1  s

Cope

 

of

 

delivery

 

1  RF output collectorHOC 168 

 

1  Brief Assembly Instructions

Содержание GAK 7100

Страница 1: ...ssembly Instructions As well as this supplementary Assembly Instructions the Assembly Instructions for the head end station apply GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 Email info gss de Internet www gss de en ...

Страница 2: ...ulations 3 2 General information 3 2 1 Scope of delivery 3 2 2 Meaning of the symbols used 4 2 3 Technical data 4 2 4 Description 4 3 Overview 5 4 Installing the RF output collector 6 5 Setting the output level 7 6 Final procedures 8 ...

Страница 3: ...ility is accepted for damage caused by faulty connections or inap propriate handling of the device Check the head end station according to the safety instructions listed in their assembly instruction Take precautions to prevent static discharge when working on the device Electronic devices should never be disposed of in the household rubbish In accordance with directive 2002 96 EC of the European ...

Страница 4: ...egulator 0 31 dB RF inputs 8 F sockets Input impedance 75 Ω RF output 1 F socket RF test output 20 dB 1 F socket Output impedance 75 Ω 2 4 Description The active RF output collector HOC 168 has 8 RF inputs one RF output and one RF test output 20 dB The RF output collector collects the output signals of the modules modulators and provides them via the output socket for the cable network Via the SET...

Страница 5: ... 5 HOC 168 3 Over view D B A C Fig 1 A Output B Connector block C Test output 20 dB D Inputs ...

Страница 6: ... of the rib bon cable to the backplane E Connect the output cable 1 fig 4 part of the packing con tents of the head end station to the output A of the RF output collector Insert the other end of the out put cable in one of the openings knock outs in the rear panel of the head end station F and tighten it Mount the RF output collector HOC 168 to the position in the head end sta tion according to fi...

Страница 7: ...T V 10 2 x M CANCEL SETUP S STORE MEMORY S M 0 31 M Bx 1A C5 12 S3 24 TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Bx 1A DVBT C 69 BE160 Press the button The Set output level OUTPUT Level menu is activated Using the buttons set the RF output level as required for the cable system Press the button The Store data MEMORY menu is activated All programmed data is saved by pressing the button You will be...

Страница 8: ... and to ensure a reliable operation Securely tighten the cable connections F connector using an open ended spanner spanner width 11 mm 1 2 2 2 Fig 6 Position the breakthroughs in the base plate above the fastening screws 2 fig 6 Push the base plate in direction of the arrow and lock it with the locking screw 1 Tighten the fastening screws 2 Tighten the nuts of retrofitted F terminals if applicable...

Страница 9: ...CE Declaration of Conformity Alterations reserved Technical data E O E by GSS GmbH 28062013 ...

Отзывы: