- 26 -
STC 4-16 CT CI
f
ilter
& Ca
200
201
202
203
204
205
209
206
207
208
210
216
218
215
217
211
212
In the
Filter & CA
menu, in the selec-
tion
PASS Services
you can remove
programs/services with table adjust-
ment from the data streams of the
transponders, modify the TS/ON IDs,
make changes in assignment of the
CA modules (CAMs) as well as define
which services should be descram-
bled. In addition you get access to the
CAM status indications as well as the
CAM menus.
In the selection
Drop PIDs
, PIDs can
be removed (dropped) from the data
streams of the transponders or have
new addresses assigned (remapped)
without adapting the tables.
—> For entering/indication of the different IDs the number format can
be set to
hexadecimal
or
decimal
in menu
System > Firmware
.
200
Select displaying the station filter.
201
Herein you can select whether only one line is displayed or all lines are
displayed.
202
By default, CAM slots 1…6 are assigned to lines 1…6. By menu point
CA
Mode
you can change the assignment of the CA slots. If one CA Module is
not enough to completely descramble a transponder, here in addition you
can assign the CA modules 6-4 to lines 1-3.
1
Line 1
Line 6
Line 2
Line 5
1–>1; 2–>2; 3–>3; 4–>4; 5–>5; 6–>6
Line 3
Line 4
6
2
5
3
4
CI 1…6 —> lines 1…6
1–>1
+
6; 2–>2; 3–>3; 4–>4; 5–>5
1
Line 1
Line 1
+
Line 2
Line 5
Line 3
Line 4
6
2
5
3
4
CI 1+6 —> line 1;
CI 2…5 —> lines 2…5