background image

Page 2 of 8

Model:

MPPT30-2L

1700W Solar Battery Charger 

Maximum Power Point Tracker

Operating Instructions

Please read these instructions before use

Important notes:

 

• 

This equipment must be installed by qualified personnel only and incorrect wiring can cause 

   fire, injury or death – GSL will accept no responsibility for MPPT misconnection or misuse.

  Use only 12V, 24V or 48V Lithium Iron Phosphate (LiFePO

4

) and confirm the MPPT settings, charge voltages and 

   currents are correct for your battery system – if in any doubt seek qualified advice!

• 

 Use only PV Systems with open circuit voltage below 95V.

  Use wires suitable for at least 40A, but if wire runs are over 3m then larger wires are recommended to limit voltage

   drop and losses. 

  Install the unit in a dry place out of direct sunlight and away from flammable liquids or gases.

  Battery fuse ( BF ) is always required and must be located as close to the battery as possible, its sizing depends

   on the wire size and load ratings. Typically a 40A 60VDC fuse would do.

 The lowest Maximum Power Point system voltages are 18V for 12V batteries, 36V for 24V batteries and 72V for 

   48V batteries to ensure full power.

 To enhance Battery and Load protection the MIHV or equivalent and a suitable BMS rated to the maximum 

   panel power and 170% of nominal battery voltage is highly recommended.

MPPT30-2L Specifications 

Efficiency typical

 96%

Input voltage 

16V to 95V

Saturation Voltage 

 

Default 14.6V / 29.2V / 58.4V

Long Life Option 14.3V / 28.6V / 57.2V

High Capacity Option

 

14.8V / 29.6V / 59.2V

Maintenance Voltage

14.1V / 28.2V / 56.4V

Output power

1700W / 30A MAX 

Quiescent current

0.05A 

Thermal protection

Multilevel Type

Dimensions (mm)

260 X 145 X 67mm

Indications

LED display –  OUTPUT STATUS

MPPT30-2L General Information:

• 

Green LED On  – Battery Ok.

 Green LED Flashing – Battery Low.

• 

Green LED Off - Fault Condition

• 

This MPPT is designed to auto detect 12V, 24V or 48V battery systems and select a suitable charge regime.

• 

The MPPT30-2L is shipped set to Nominal Charge which is the safest setting. If you require, Long Life or 

   High Capacity Charging then 

BEFORE

 wiring the MPPT in, follow the 

CHANGING CHARGE TYPE SETTING

   PROCEDURE.

• 

The maximum Saturation voltage is (when set to High Capacity) 14.8V, 29.6V or 59.2V and the Maintence voltage

   is 14.1V, 28.2V or 56.4V for 12V, 24V or 48V batteries respectively.

 The saturation phase is entered following a low battery condition at dawn and is maintained for the rest of the day. 

  Otherwise Maintenance voltage is applied. 

 Custom voltages and thresholds are possible but minimum orders apply.

 This MPPT has a built in multilevel over temperature protection to improve product reliability while maximising 

   output power availability. 

 The maximum continuous output power is 1700W in 48V systems, 850W in 24V systems and  425W in 12V 

   systems. The output current is limited to 30A.

• 

The threshold before the charger will enter a Saturation charge is 13.9V / 27.8V / 55.6V

Содержание MPPT30-2L

Страница 1: ...8 and 09 and the Greentech Consensus Awards 09 A simple compact and low cost alternative Ideal for charging batteries from new low cost and high efficiency panels The MPPT30 2L is designed to automatically charge 12V 24V and 48V Lithium Iron Phosphate batteries from silicon based pv panels such as monocrystalline polycrystalline and thin film It has a built in Load Over Voltage switch configurable...

Страница 2: ...iency typical 96 Input voltage 16V to 95V Saturation Voltage Default 14 6V 29 2V 58 4V Long Life Option 14 3V 28 6V 57 2V High Capacity Option 14 8V 29 6V 59 2V Maintenance Voltage 14 1V 28 2V 56 4V Output power 1700W 30A MAX Quiescent current 0 05A Thermal protection Multilevel Type Dimensions mm 260 X 145 X 67mm Indications LED display OUTPUT STATUS MPPT30 2L General Information Green LED On Bat...

Страница 3: ...ltage Disconnect Figure 2 This option protects the Load from receiving a High Voltage The MPPT voltage goes over 1V above its maximum programed value This protects the load from overvoltage spikes such as disconnection of the battery or faults with in the system Most LiFePo4 are fitted with over voltage disconnects from their onboard charge controllers and are already protected against Over Voltag...

Страница 4: ...s are loads which can be disconnected to ensure maximum on time for critical loads as well as to extend the life expectancy and reliability of the system The non critical load can be set up as Dawn to Dusk loads via MCM Wiring with MCM option Connecting the optional MCM to the MPPT will allow various system parameter display output voltage and alarm settings and enable the programmable dawn to dus...

Страница 5: ... 42 32 63 48 84 64 42 32 84 64 Grid Connect Panel size no cells in grid 1x18 Cell Grid 10 8 1x48 Cell Grid 28 23 2x48 Cell Grid 56 46 3x48 Cell Grid 84 69 1x52 Cell Grid 31 25 2x52 Cell Grid 62 50 3x52 Cell Grid 93 75 1x54 Cell Grid 32 26 2x54 Cell Grid 64 52 3x54 Cell Grid 96 78 1x60 Cell Grid 36 29 2x60 Cell Grid 72 58 1x72 Cell Grid 44 36 2x72 Cell Grid 88 72 1x96cgsp 65 55 For optimal performa...

Страница 6: ...ront panel screws and the front panel and slide out cover see Figure 4 3 Locate connector J4 By default this will be Jumperless Nominal Setting see Figure 4 4 Shift link on J4 to desired battery setting High Capacity see Figure 5 Long Life See Figure 6 5 Slide back cover and fit in front panel carefully ensuring led is still visible through the faceplate and screw back the 7 mounting screws The ab...

Страница 7: ...cal application which can be used for higher loads or longer run times or cutting PV system cost 2 Suitable for lower cost non battery type PV since the MPPT can efficiently charge the batteries from relatively high voltage say 12V batteries from 40V MPP panels 3 Less interference and more accurate voltages during saturation and maintenance Q What happens at low PV currents The MPPT will outperfor...

Страница 8: ...V 1600W panel the MPPT30 will supply a daily load of 400W for about 10 hours Q Is interference possible and If so what do I do GSL s MPPTs produce far less interference than a conventional solar regulator during the absorption and float stages that is during most of its operating time and it is designed to comply with local and international EMI standards however some interference is still possibl...