GSK CNC Equipment Co., Ltd.
62
Occurring in switching
on control power
supply
①
Circuit board is at fault.
①
Change the servo driver.
①
The motor runs exceeding
rated torque.
①
Check the load.
②
Reduce the start-stop
frequency.
③
Reduce the torque limit
value.
④
Change the driver and
motor with the larger power
ones.
①
Hold brake is not on.
①
Check the hold brake.
①
Motor vibrates unsteadily.
①
Adjust the gain.
②
Increase the acceleration/
deceleration time.
③
Reduce the load inertia.
Err-13 Overload
Occurring in motor
running
①
One of U, V, W phases is
broken off.
②
The connection of encoder
is mistaken.
①
Check the connection.
Occurring in switching
on control power
supply
①
Circuit board is at fault.
①
Change the servo driver.
①
Brake resistance connection
is broken off.
①
Connect the wire again.
①
Brake transistor is
damaged.
②
Internal brake resistance is
③
damaged.
①
Change the servo driver.
Err-14
Brake circuit
fault
Occurring in motor
running
①
Brake loop capacity is not
enough.
①
Reduce the start-off
frequency.
②
Increase the acceleration/
deceleration time constant.
③
Reduce the torque limit
value.
④
Reduce the load inertia.
⑤
Change the driver and
motor with larger power
ones.
Содержание DA98B
Страница 1: ...GSK DA98B AC Servo Drive Unit User Manual ...
Страница 2: ......
Страница 9: ...Warning Ⅴ Notes ...
Страница 10: ...GSK CNC Enquipment Co Ltd Ⅵ ...
Страница 12: ...GSK CNC Enquipment Co Ltd 2 ...
Страница 28: ...GSK CNC Equipment Co Ltd 16 Fig 3 4 Terminals and definition of CN1 ...
Страница 77: ...Chapter 8 Isolated transformer 65 Fig 8 2 Outline and installation dimensions for BS 200 model ...
Страница 78: ...GSK CNC Equipment Co Ltd 66 Fig 8 3 Outline and installation dimensions for BS 300 model ...
Страница 79: ...Chapter 8 Isolated transformer 67 Fig 8 4 Outline and installation dimensions for BD 80 model ...
Страница 80: ...GSK CNC Equipment Co Ltd 68 Fig 8 5 Outline and installation dimensions for BD 120 model ...
Страница 87: ......