GSi PNEG-1894 Скачать руководство пользователя страница 25

Limited Warranty — N.A. Grain Products

The GSI Group, LLC. (“GSI”) warrants products which it manufactures, to be free of defects in materials and workmanship
under normal usage and conditions for a period of 12 months from the date of shipment (or, if shipped by vessel, 14
months from the date of arrival at the port of discharge). If, in GSI’s sole judgment, a product is found to have a defect in
materials and/or workmanship, GSI will, at its own option and expense, repair or replace the product or refund the
purchase price. This Limited Warranty is subject to extension and other terms as set forth below.

Warranty Enhancements:

The warranty period for the following products is enhanced as shown below and is in

lieu of (and not in addition to) the above stated warranty period. (Warranty Period is from date of shipment.)

Product

Warranty Period

Storage

Grain Bin Structural Design
▪ Sidewall, roof, doors, platforms and walkarounds
▪ Flooring (when installed using GSI specified floor support system for that floor)
▪ Hopper tanks (BFT, GHT, NCHT, and FCHT)

5 Years

Conditioning

Dryer Structural Design – (Tower, Portable and TopDry)
▪ Includes (frame, portable dryer screens, ladders, access doors and platforms)

5 Years

All other Dryer parts including:
▪ Electrical (controls, sensors, switches and internal wiring)

2 Years

All Non-PTO Driven Centrifugal and Axial Fans

3 Years

Bullseye Controllers

2 Years

Material
Handling

Bucket Elevators Structural Design

5 Years

Towers Structural Design

5 Years

Catwalks Structural Design

5 Years

Accessories (stairs, ladders and platforms) Structural Design

5 Years

Conditions and Limitations:

THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH
HEREIN; SPECIFICALLY, GSI DISCLAIMS ANY AND ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE OR USE IN CONNECTION WITH: (I) ANY PRODUCT MANUFACTURED OR SOLD BY GSI,
OR (II) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT,
REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION,
LAYOUT, SUITABILITY FOR A PARTICULAR PURPOSE, OR DESIGN OF SUCH PRODUCTS.

The sole and exclusive remedy for any claimant is set forth in this Limited Warranty and shall not exceed the amount paid
for the product purchased. This Warranty only covers the value of the warranted parts and equipment, and does not cover
labor charges for removing or installing defective parts, shipping charges with respect to such parts, any applicable sales
or other taxes, or any other charges or expenses not specified in this Warranty. GSI shall not be liable for any other direct,
indirect, incidental or consequential damages, including, without limitation, loss of anticipated profits or benefits. Expenses
incurred by or on behalf of a claimant without prior written authorization from the GSI warranty department shall not be
reimbursed. This warranty is not transferable and applies only to the original end-user. GSI shall have no obligation or
responsibility for any representations or warranties made by or on behalf of any dealer, agent or distributor. Prior to
installation, the end-user bears all responsibility to comply with federal, state and local codes which apply to the location
and installation of the products.

This Limited Warranty extends solely to products sold by GSI and does not cover any parts, components or materials used in conjunction with the
product, that are not sold by GSI. GSI assumes no responsibility for claims resulting from construction defects, unauthorized modifications,
corrosion or other cosmetic issues caused by storage, application or environmental conditions. Modifications to products not specifically
delineated in the manual accompanying the product at initial sale will void all warranties. This Limited Warranty shall not extend to products or
parts which have been damaged by negligent use, misuse, alteration, accident or which have been improperly/inadequately maintained.

Notice Procedure:

In order to make a valid warranty claim a written notice of the claim must be submitted, using the RMA form, within 60 days of discovery of a
warrantable nonconformance. The RMA form is found on the OneGSI portal.

Service Parts:

GSI warrants, subject to all other conditions described in this Warranty, Service Parts which it manufactures for a period of 12 months from the
date of purchase unless specified in Enhancements above.

(Limited Warranty - N.A. Grain Products_ revised 01 October 2020)

Содержание PNEG-1894

Страница 1: ...PNEG 1894 TopDry Chute Controller Installation Manual PNEG 1894 Version 5 1 Date 09 27 20...

Страница 2: ...te Controller All information illustrations photos and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at a...

Страница 3: ...stallation for TopDry System 13 Locating the Chute Pulley Assembly 13 Attaching the Mounting Plate and Gussets to the Stiffener 15 Assembling the Chain Guard 17 Installing the Housing Assembly 18 Test...

Страница 4: ...must stay out of the work area at all times Alterations must not be made to the equipment Alterations can produce dangerous situations resulting in SERIOUS INJURY or DEATH This equipment must be insta...

Страница 5: ...is symbol indicates an imminently hazardous situation which if not avoided will result in serious injury or death This symbol indicates a potentially hazardous situation which if not avoided can resul...

Страница 6: ...owed exactly a fire or explosion can result causing property damage personal injury or loss of life Carefully read all safety messages in this manual and safety signs on your machine Keep signs in goo...

Страница 7: ...Equipment Properly Make sure grain chutes are empty by performing a manual dump before entering the bin Before attempting to remove and reinstall the fan blade contact GSI for the recommended procedu...

Страница 8: ...wear personal protective equipment PPE as needed Complete a permit to work and follow all permit required confined space entry procedures defined by the site manager Make sure that the area has been...

Страница 9: ...Off Sheet Below is a sign off sheet that can be used to verify that all personnel have read and understood the safety instructions This sign off sheet is provided for your convenience and personal re...

Страница 10: ...pressure may damage roof Use positive aeration system Make sure all roof vents are open and unobstructed Start roof fans when supply fans are started Do not operate when conditions exist that may cau...

Страница 11: ...sidedraw wall discharge systems UNLOADING INSTRUCTIONS Failure to heed these warnings could result in serious injury death structural damage or collapse of tank DC GBC 2A D placer des pi ces peut cra...

Страница 12: ...12 PNEG 1894 TopDry Chute Controller 3 Controller Layout Figure 3A Chute Pulley Cable Location...

Страница 13: ...the chute controller location before installing the stiffener mounting plate Locating the Chute Pulley Assembly 1 Position the pulley in the hole that is located 9 3 8 23 8 cm horizontally from the c...

Страница 14: ...4 Installation 14 PNEG 1894 TopDry Chute Controller Figure 4C...

Страница 15: ...all six 6 holes in the stiffener using the mounting plate as a template for hole locations making sure that the holes are drilled on the peaks of corrugation ridge 3 Attach the stiffener mounting pla...

Страница 16: ...tiffener mounting plate A using three 3 flange bolts E and nuts F for each mounting gusset See Figure 4E Figure 4E Ref Part Description A TD 101327 Stiffener Mounting Plate D TD 101326 Lower Mounting...

Страница 17: ...tightening with flange nuts E See Figure 4F 3 Feed chain A that is part of the chute position controller drive from the chute position controller around the small sprocket and out through the back pan...

Страница 18: ...ld drill all four 4 holes in the bin sidewalls through the four 4 holes in the sidewall mounting brackets D making sure that the holes are drilled on the peaks of the corrugation ridges Use bolts to a...

Страница 19: ...ed the tamper switch B must be depressed a Use tape to secure tamper switch in the depressed position b Ensure the sprocket C is in the open position when beginning testing Use the manual dump chute s...

Страница 20: ...he Turnbuckle 1 Run the cable from the inside of the bin through the sidewall sheet over the chute pulley on the bin eave and down to the chain tunbuckle from the controller See Figure 4I Figure 4I Re...

Страница 21: ...e D to the halfway point to allow for adjustment in both directions See Figure 4J Figure 4J 3 Bolt the turnbuckle to the chain C See Figure 4J 4 Attach the cable to the turnbuckle using cable clamps E...

Страница 22: ...he chutes via chains The controller retracts the cable to close the chutes or extends the cable to open the chutes 2 Dump chutes should be level in the closed position Use the turnbuckle to adjust the...

Страница 23: ...PNEG 1894 TopDry Chute Controller 23 5 Wiring and Schematic Diagrams Actuator Wiring Schematic...

Страница 24: ...5 Wiring and Schematic Diagrams 24 PNEG 1894 TopDry Chute Controller TopDry Chute Control Panel Wiring Schematic...

Страница 25: ...DESIGN OF SUCH PRODUCTS The sole and exclusive remedy for any claimant is set forth in this Limited Warranty and shall not exceed the amount paid for the product purchased This Warranty only covers th...

Страница 26: ...be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62510 0020 Phone 1 217 226 4421 Fax 1 217 226 4420...

Отзывы: