PNEG-1499
Digital High/Low Thermostat
11
4. Electrical Connection
Standard electrical safety practices and codes should be used when working with a heater. Refer to the
National Electric Code Standard Handbook by the National Fire Protection Association.
A qualified
electrician should make all wiring installations.
Thermostat Connection to Standard Heater Control
Thermostat Connection to Standard Terminal Strip on Heaters Built
Prior to 2007.
1. Connect power cord to fan control box.
2. Connect the BLACK 120VAC power wire to terminal 2.
3. Connect the WHITE Neutral wire to terminal 8.
4. Connect the GREEN Stage 1 Common wire to terminal 6.
5. Connect the RED Stage 1 N.O. wire to the high/low light and cycle solenoid.
6. Connect the ORANGE Stage 2 Common wire to terminal 8.
7. Connect the BLUE Stage 2 N.O. wire to terminal 5.
Figure 4A Heaters Built Before 2007 (HF-7356 Flame Probe Checking Terminal Strip)
Always disconnect and lock out power before working on or around heater.