Appendix G: Safety Characteristics and Certification
9
Surge immunity test
EN61000-4-5 :
2005
On the main sector : L-PE : ±2kV L-L : ±1kV I/O : L-
PE : ±1kV L-L : ±1kV
10
Power frequency mag-
netic field immunity test
EN 61000-4-8 :
2009
30 A/m
11
Voltage dips, short inter-
ruptions and voltage var-
iations immunity tests
EN61000-4-11 :
2004
0%, 1, 1 cycle: Performance A (B) 40%, 1,10
cycles: Performance A (C) 70%, 1, 25 cycles: Per-
formance A (C) 0%, 1, 250 cycles: Performance A
(C)
According to EN61326-1 the definitions of performance criteria are as follows:
• Performance criterion A — During test normal performance within the specification limits
• Performance criterion B — During test, temporary degradation, or loss of function or performance
which is self-recovering
• Performance criterion C — During test, temporary degradation, or loss of function or performance
which requires operator intervention or system reset occurs.
Phone circuit safety characteristics
The phone card is designed and tested to meet the following requirements:
• UL 60950-1 second edition and CAN/CSA-C22.2 no 60950-1 second edition in the section 6.
• NSI/TIA-968-B (Telecommunications, Telephone Terminal Equipment, Technical Requirements for
Connection of Terminal Equipment to the Telephone Network, Approved: August 11, 2009 TIA-968-B-
1 Addendum 1, June 2012).
• FCC standard Part 68 ( FCC rules for Registration of Telephone Equipment).
• CS-03 Part I (Issue 9 Amendment 4, December 2010, requirements for terminal equipment and
related access arrangements intended for direct connection to analogue wireline facilities).
The phone card, model PCB402 (300-00319), the ACTA number is US:32ZCN01BGSIE0001. The phone
card, model PCB402 (300-00319), the IC number is IC: 11880A-PCB402RP002.
Environmental characteristics
Parameter
Condition
Value
Temperature Operating
battery installed
0 to 40 °C (32 to 104 °F)
Storage
-20 to +60 °C (-4 to +140 °F)
Humidity (Maximum Rela-
tive) Operating
0 to 10 °C (32 to 50 °F)
Non condensing
10 to 30 °C (50 to 86 °F)
95 % (± 3%) Non condensing
30 to 40 °C (86 to 104 °F)
95 % (± 3%) Non condensing
Storage
Non condensing
Altitude
7900 Ft. Max (2000 Meters Max)
Electromagnetic
Environment
EN/IEC61326-1
Enclosure Protection
IP51, ref : IEC60529
Impact rating (IK)
08
112
895–00677
Agri Alert 128 Touch
Содержание Agri-Alert 128 Touch
Страница 14: ...NOTES 14 895 00677 Agri Alert 128 Touch...
Страница 20: ...NOTES 20 895 00677 Agri Alert 128 Touch...
Страница 30: ...NOTES 30 895 00677 Agri Alert 128 Touch...
Страница 38: ...NOTES 38 895 00677 Agri Alert 128 Touch...
Страница 44: ...NOTES 44 895 00677 Agri Alert 128 Touch...
Страница 64: ...Chapter 9 Configuring a 0 5 Volt Zone Type 64 895 00677 Agri Alert 128 Touch...
Страница 66: ...NOTES 66 895 00677 Agri Alert 128 Touch...
Страница 82: ...NOTES 82 895 00677 Agri Alert 128 Touch...
Страница 88: ...NOTES 88 895 00677 Agri Alert 128 Touch...
Страница 92: ...NOTES 92 895 00677 Agri Alert 128 Touch...
Страница 96: ...NOTES 96 895 00677 Agri Alert 128 Touch...
Страница 100: ...NOTES 100 895 00677 Agri Alert 128 Touch...
Страница 102: ...NOTES 102 895 00677 Agri Alert 128 Touch...
Страница 106: ...NOTES 106 895 00677 Agri Alert 128 Touch...
Страница 107: ...F Wiring Diagram with Terminals 895 00677 Agri Alert 128 Touch 107...
Страница 108: ...Appendix F Wiring Diagram with Terminals Wiring diagram with a DPST disconnect switch 108 895 00677 Agri Alert 128 Touch...
Страница 109: ...Appendix F Wiring Diagram with Terminals Wiring diagram with a SPST disconnect switch 895 00677 Agri Alert 128 Touch 109...
Страница 110: ...NOTES 110 895 00677 Agri Alert 128 Touch...
Страница 118: ......