2. Component Installation
PNEG-1405
Moisture Controller
11
Figure 2L Weather Sensor
9. To mount the weather sensor, find a location away from any heated air coming from the dryer (conduit
is not needed for the weather sensor cable). Feed the cable through the 1-3/32" diameter hole in the
bottom of the control box and secure with the electrical screw bushing.
10. Put cable ties approximately every 4'' to hold all loose wires and cables in place. Do not tie any of
these wires to AC leads. Cut off cable tie ends.
After all the components, conduits and wire are in place proceed to the electrical connections starting
with
Step 1 on Page 12
.