Moisture Controller

Installation Manual

PNEG-1405

Version: 2.0

Date: 03-09-16

PNEG-1405

Содержание PNEG-1405

Страница 1: ...Moisture Controller Installation Manual PNEG 1405 Version 2 0 Date 03 09 16 PNEG 1405...

Страница 2: ...Controller All information illustrations photos and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any...

Страница 3: ...of Contents PNEG 1405 Moisture Controller 3 Contents Chapter 1 Safety 4 Safety Guidelines 4 Safety Instructions 5 Chapter 2 Component Installation 7 Chapter 3 Electrical Connections 12 Chapter 4 Warra...

Страница 4: ...and its safety instructions is a misuse of the equipment and may lead to serious injury or death DANGER WARNING CAUTION CAUTION This is the safety alert symbol It is used to alert you to potential pe...

Страница 5: ...in all cases Authorities having jurisdiction should be consulted before installations are made Follow Safety Instructions Carefully read all safety messages in this manual and safety signs on your ma...

Страница 6: ...otect your hands from sharp edges on plastic or steel parts Wear steel toe boots to help protect your feet from falling debris Tuck in any loose or dangling shoestrings A respirator may be needed to p...

Страница 7: ...7 2 Component Installation Location for the Moisture control box second and third leg back from dryer control box Figure 2A Moisture control box leg channel D01 1656 Figure 2B Moisture control box leg...

Страница 8: ...bolts and 3 8 16 flanged nuts as shown in Figure 2C Moisture control box installed D03 0552 Figure 2D 2 Install moisture control box onto leg channels installed in Step 1 using 3 8 16 x 1 flanged bolt...

Страница 9: ...ep 3 on Page 8 as shown in Figure 2H Figure 2H Moisture sensor installed 5 Connect the ground wire A for the Moisture Sensor to the rear auger bearing plate as shown in Figure 2H 6 Run the shielded wi...

Страница 10: ...through the black flex conduit and connect conduit to the Moisture Manager control box 8 To mount the plenum thermocouple knock out one of the prepunched wholes in either the front or rear column end...

Страница 11: ...sensor cable Feed the cable through the 1 3 32 diameter hole in the bottom of the control box and secure with the electrical screw bushing 10 Put cable ties approximately every 4 to hold all loose wir...

Страница 12: ...Moisture Sensor installed in Step 4 on Page 9 and strip insulation 1 4 for the individual wires and connect them to the terminal strip according to the decal below it i e green to GN Figure 3A Locati...

Страница 13: ...1 4 for the individual wires and connect them to the terminal strip as shown in Figure 3B Figure 3B Ref Description Ref Description A White Terminal 11 D Red Terminal 7 B Black Terminal 10 E Green Te...

Страница 14: ...l wires of the Plenum Thermocouple installed in Step 8 on Page 10 and connect them to the terminal strip as shown in Figure 3C Figure 3C Ref Description A Red Terminal 6 B White Terminal 5 Location of...

Страница 15: ...c Control Box GN BK 1 2 DC VOLTMETER WY WR BR 3 4 5 SPEED CONTROL GND L1 N GN V W C 1 2 3 4 5 6 7 115 VAC INPUT 115 VAC TO CHART RECORDER SIG O NOTES 1 Connect wires to bottom section of terminal stri...

Страница 16: ...16 PNEG 1405 Moisture Controller NOTES...

Страница 17: ...SI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and exclusive remedy is set forth in th...

Страница 18: ...refully followed in all cases Authorities having jurisdiction should be consulted before installations are made GSI Group 1004 E Illinois St Assumption IL 62510 0020 Phone 1 217 226 4421 Fax 1 217 226...