GSD GSDn-WEC Скачать руководство пользователя страница 6

10

Network Diagrams

Network Diagrams for Multiple Controllers

19200

9600

12V - 1
  0V - 2
    B - 3
    A - 4

A

B

0V

TX

RX

PC Direct

12V

PC Network

Connect using RS232-RS485

cable to serial port on PC

PC Network Connections, when using more

than one GSD Controller.

Daisy chain the PC network A , B , 0V to each controller.

Set an individual address for each controller

between 1 & 3 using the dip switches

(see below )

RS485 Converter

A

B

0V

TX

RX

PC Direct

Controller 1

Controller 2

PC Network

 Address 1 - Set SW1 ON        Address 2 - Set SW2 ON     Address 3 - Set SW3 ON

Controller 1

Controller 2

Set Baud Rate to 19200

Daisy  Chain

each controller

A

B

0V

1 2 3 4

Controller 3

OFF

ON

1 2 3 4

OFF

ON

1 2 3 4

OFF

ON

Setting the GSD Controller address

Direct Connect - All OFF        Address 1 - Set SW1 ON     Address 2 - Set SW2 ON
Note: Address 3 - Set SW3 ON only

The Controller Address is set by configuring the Dip switches as shown below.

Configuring GSD Controller Communications

Step   Description

  1.       Click ‘Settings’ tab to open communications window. Select the Serial Port
            Number connected to the Controller.

OFF

ON

1 2 3 4

OFF

ON

1 2 3 4

OFF

ON

1 2 3 4

 11

Network Diagrams

Restoring Factory Settings

Example: All Dip Switches are set to the ON position.

To restore the factory default setting , Set 

ALL

 Dip

Switches 1,2,3 & 4 to the ON position and then

power-up the GSD Controller.

OFF

ON

1 2 3 4

Note: Factory Default settings will be restored after

powering up the controller with All dip-switches ON. The
dip-switches’s should then be set to the controller

address as shown above in section “Setting the GSD
controller address”

Содержание GSDn-WEC

Страница 1: ...less Network System GSD Wi Max System is the next generation in access control solutions It provides a Wireless Network throughout the premises giving the convenience and security of a fully networked...

Страница 2: ...Output Mapping Supports Wireless RS485 Networks Automatic Backup Facility Database Encryption 20 20000 128 128 128 Yes Yes Unlimited CCTV Lift control Yes Yes Yes Installation Steps Step Description...

Страница 3: ...pull out on right and slide left to remove cover pull forward on right and slide left mount with 4 x 1 5 inch No 8 Security Type screws rear tamper switch cable entry cable entry cable entry cable en...

Страница 4: ...view 50 meters 50 meters 50 meters 50 meters 50 meters 50 meters Note If using a single Controller an RS232 cable may be used Max cable length 10 meters RS485 Connection to Door Controls Door Control...

Страница 5: ...Warning Installation should only be carried out by a suitably qualified person only Cable Tie retaining clips Main Input Cable 230VAC Neutral Earth Live Remove Battery Tab Pull 9 Network Diagrams for...

Страница 6: ...he GSD Controller address Direct Connect All OFF Address 1 Set SW1 ON Address 2 Set SW2 ON Note Address 3 Set SW3 ON only The Controller Address is set by configuring the Dip switches as shown below C...

Страница 7: ...e new IP Address settings are applied 9 Connect the PC and Controller to your LAN and enter the new IP address to allow the application to communicate with the Controller Note Reset the IP address on...

Страница 8: ...troller is on line 15 Operation Instructions Phase 2 Configuring the GSD Controller Step Description 1 Open the Doors tab in the main menu to add the required number of new doors to be part of this ne...

Страница 9: ...Scan Mode the Red Led on the Door Control will now be in flicker mode as an indication 17 Operation Instructions Phase 3 Enrolling Door Controls Note For Wired 485 Door Controls right click on the Co...

Страница 10: ...rol Example Disabling cards fobs Enabling PIN codes only on a Wi PIN Prox Set the Timed Action Card or PIN to Inactive and setting the Timed Action PIN Only to All day Every Day This will grant access...

Страница 11: ...om the All available Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Step Description After all users access levels and door control...

Страница 12: ...ot store the finger print It uses an algorithm to generate a binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint Incorrect F...

Страница 13: ...Correct Finger Placement 24 Finger Placement Wi BIO Incorrect Finger Placement 25 Finger Placement Wi BIO...

Страница 14: ...14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 Ctrl Door No Door Type Door Location Name Walk Test 1 2 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Ctrl Door No Door Typ...

Отзывы: