GSD GSDn-WEC Скачать руководство пользователя страница 4

 6

System Overview

Wireless Connection to Door Controls

Door Control

        #1

Door Control

        #2

Door Control

        #3

Door Control

      #5 - 20

TCP-IP connection to Controllers

or

RS485 Network to Controllers
Max number of Controllers 3

Max Cable Length 1.4 km

Controller

      #1

Controller

 #2 - 3

Door Control

        #4

Note: Door Controls can be installed within 50 meters

of the Controller or within 50 meters of any other Door Control

as each Door Control will function as a repeater. Each repeater
transmits data to/from the Controller.

50 meters

 7

System Overview

50 meters

50 meters

50 meters

50 meters

50 meters

50 meters

Note: If using a single Controller,

an RS232 cable may be used.

Max cable length 10 meters

RS485 Connection to Door Controls

Door Control

        #1

Door Control

        #2

Door Control

        #3

Door Control

      #4 - 20

RS485 Network to Door Controls

Max Cable Length 1.4 km.

Daisy Chain Configuration Only.

Controller

      #1

Controller

 #2 - 3

Note: If using a single Controller,

an RS232 cable may be used.

Max cable length 10 meters

Place a 120ohm

Termination Resistor
across A & B on the last

Door Control in the chain.

Place a 120ohm
Termination Resistor

across A & B on the

Controller

TCP-IP connection to Controllers

or

RS485 Network to Controllers
Max number of Controllers 3

Max Cable Length 1.4 km

Содержание GSDn-WEC

Страница 1: ...less Network System GSD Wi Max System is the next generation in access control solutions It provides a Wireless Network throughout the premises giving the convenience and security of a fully networked...

Страница 2: ...Output Mapping Supports Wireless RS485 Networks Automatic Backup Facility Database Encryption 20 20000 128 128 128 Yes Yes Unlimited CCTV Lift control Yes Yes Yes Installation Steps Step Description...

Страница 3: ...pull out on right and slide left to remove cover pull forward on right and slide left mount with 4 x 1 5 inch No 8 Security Type screws rear tamper switch cable entry cable entry cable entry cable en...

Страница 4: ...view 50 meters 50 meters 50 meters 50 meters 50 meters 50 meters Note If using a single Controller an RS232 cable may be used Max cable length 10 meters RS485 Connection to Door Controls Door Control...

Страница 5: ...Warning Installation should only be carried out by a suitably qualified person only Cable Tie retaining clips Main Input Cable 230VAC Neutral Earth Live Remove Battery Tab Pull 9 Network Diagrams for...

Страница 6: ...he GSD Controller address Direct Connect All OFF Address 1 Set SW1 ON Address 2 Set SW2 ON Note Address 3 Set SW3 ON only The Controller Address is set by configuring the Dip switches as shown below C...

Страница 7: ...e new IP Address settings are applied 9 Connect the PC and Controller to your LAN and enter the new IP address to allow the application to communicate with the Controller Note Reset the IP address on...

Страница 8: ...troller is on line 15 Operation Instructions Phase 2 Configuring the GSD Controller Step Description 1 Open the Doors tab in the main menu to add the required number of new doors to be part of this ne...

Страница 9: ...Scan Mode the Red Led on the Door Control will now be in flicker mode as an indication 17 Operation Instructions Phase 3 Enrolling Door Controls Note For Wired 485 Door Controls right click on the Co...

Страница 10: ...rol Example Disabling cards fobs Enabling PIN codes only on a Wi PIN Prox Set the Timed Action Card or PIN to Inactive and setting the Timed Action PIN Only to All day Every Day This will grant access...

Страница 11: ...om the All available Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Step Description After all users access levels and door control...

Страница 12: ...ot store the finger print It uses an algorithm to generate a binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint Incorrect F...

Страница 13: ...Correct Finger Placement 24 Finger Placement Wi BIO Incorrect Finger Placement 25 Finger Placement Wi BIO...

Страница 14: ...14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 Ctrl Door No Door Type Door Location Name Walk Test 1 2 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Ctrl Door No Door Typ...

Отзывы: