GRAPHS FOR THE HEAD AVAILABLE TO THE SYSTEM
INSTALLATION
Pict. 17
0
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
120
180
240
300
360
540
600
660
720
840
900
960
1080
5.5
6
420
480
780
1020
1140
1260
1200
Q L/h
Dp mCa
for 15-60 (Symona 28/32Kw)
for 15-50 (Symona 24Kw)
Use:
The boiler has been constructed according
to current technical standards and the most
stringent safety rules. Despite this, improper
use may endanger persons and property as
well as damaging the boiler itself.
This boiler has been designed as a thermal
generator for closed-loop central heating
systems and for the production of domestic
hot water.
This boiler is only for heating water to a
temperature below that of boiling point at
atmospheric temperature.
Any use different from those outlined herein is
to be considered improper. The manufacturer/
supplier declines any responsibility for
damage or injury caused by improper use.
Use of the boiler according to its design also
means respecting the instructions given in
the operation and maintenance manuals
and observing the general inspection and
maintenance conditions.
General requirements
• Installation must only be performed by
qualified and licensed personnel. They also
assume responsibility for correct installation,
adjustment and commissioning.
Adjustment, maintenance and repair of the
boiler must only be performed by qualified
and authorised personnel.
• Do not install the boiler in environments
containing dust or strong vapours.
The presence of substances such as fluorine,
chlorine, sulphur etc. (e.g. vapours from
sprays, solvents or detergents, paints,
adhesives or fuels) may cause the boiler’s
components or combustion gas evacuation
system to corrode and become damaged.
Avoid installing the boiler directly in
commercial/industrial premises (e.g. hair
salons, painting/carpentry workshops,
cleaning companies etc.).
• The boiler must be installed in ventilated
premises.
• Install the device respecting the minimum
distances and spaces in Pict. 18 (also when
installing inside an enclosure).
• Mount the boiler on a solid wall.
• Ensure that there are no depressions which
could cause the boiler to stand out from the
wall.
• Ensure you do not drill into tracked cables
or piping when drilling.