- 4 - 

STC 816 R

n

otes

 

about

 

safet y

 

and

 

hazards

 •  The head-end station is subject to the regulations of protection class I.

 

•  Never operate the device without a protective earth connection, earth con-

nection to the device and potential equalisation!

 

•   Observe the relevant VDE regulations.

 

•  If the power cord needs to be replaced, only use an OEM power cord (EMC).

 

•  The standards EN/DIN EN 50083 resp. IEC/EN/DIN EN 60728 must be 

observed, especially concerning equipotential bonding and earthing.

 

•  Observe the relevant standards, regulations and guidelines on the installa-

tion and operation of antenna systems. 

 

•  Before starting installation or service work disconnect the receiving system 

from mains. For a complete disconnection from the mains, the mains plug 
must be pulled out of the mains socket. Ensure that the mains plug can be 
pulled out without difficulties.

 

•  Do not perform installation and service work during thunderstorms.

  •  Assembly, installation and servicing must be carried out by an authorised 

electrician.

 

• 

The head-end station should only be installed in a room where the permissi-
ble ambient temperature range (0 °C and +50 °C ) can be maintained, even 
during fluctuations in climatic conditions.

 

• 

Make sure there is a minimum space 

 

-  at wall mounting 50 cm above and below

 

-  at mounting in a 19" cabinet 20 cm above and below, as well as 10 cm 

behind.

 

  To  avoid  too  strong  heating  of  the  head-end  stations  it  is  not  admissible 

to mount them one upon the other without using thermic precautions (e.g. 
permanently air recirculation, ventilation, heat deflectors etc.).

 

•  If additional fans are to be used to circulate the air, ensure that the system will 

be shut down (disconnected from mains) should any one of the fans fail.

 

•  Install the head-end station 

 

-  in a dry, dust-free environment

 

-  in such a manner that it is protected from moisture, fumes, splashing wa-

ter and dampness

 

-  where it is protected from direct exposure to sunlight

 

-  on a vibration-free wall or floor construction

 

-  not within the immediate vicinity of heat sources

 

• 

In case of the formation of condensation wait until the system is completely 
dried.

 

•  Ensure that the head-end station is adequately ventilated. 

Содержание GSS STC 816 R

Страница 1: ...Assembly Instruction STC 816 R...

Страница 2: ...4 1 Remove front cover 12 4 2 Mounting the head end station 12 Wall mounting 13 Mounting in a 19 cabinet 14 5 Installing a cassette 15 6 Connecting the head end station 16 7 1 Potential equalisation P...

Страница 3: ...ormation about the head end station 28 System information output collector 29 System information temperature 29 System information number of the head end station 30 System information clock frequency...

Страница 4: ...y an authorised electrician The head end station should only be installed in a room where the permissi ble ambient temperature range 0 C and 50 C can be maintained even during fluctuations in climatic...

Страница 5: ...panels are all examples of combustible bases Avoid short circuits To ensure electromagnetic compatibility make sure all connections are tight and that the covers are screwed on securely No liability i...

Страница 6: ...Important note Performing works Danger by electrical shock General note 2 2 Scope of delivery 1 STC 816 R head end station without cassettes 1 Brief assembly instructions 2 Power cords 2 3 Available...

Страница 7: ...age 12 V 1 A total short circuit proof Other operating voltage 12 V 1 A total not short circuit proof use with appropriate external fuse only RS 232 socket data interface for software update and remot...

Страница 8: ...ed to 2 x 4 6 outputs The cassettes RF output signals are accumulated in a programmable RF output collector and then directed to the RF output When the head end station is shipped from the factory the...

Страница 9: ...end sta tion must not be operated without this front cover 3 2 Connectors and components Front view side view type label Fig 2 2 2 4 5 2 2 3 6 K W 7 2 Mounting screws for front cover 3 Cassette slots...

Страница 10: ...ibutor or LAN terminals 6 Openings for cable terminals 7 Control unit W Connector for peripheral devices 12 V max 1 A K Type label View from below Fig 3 0 8 9 8 RF output of the head end station 9 Dis...

Страница 11: ...LC display 9 pin D SUB socket to update the operating software to connect the HRCU 8 RCU 1 management unit Control buttons control panel Standby voltage indicator Power supply units Fig 6 Socket for m...

Страница 12: ...o avoid too strong heating of the head end stations it is not admissible to mount them one upon the other without using thermic precautions e g permanently air recirculation ventilation heat deflector...

Страница 13: ...and above is minimum 50 cm The distance of the upper holes is 413 mm Fig 8 413 mm 30 mm 30 mm Screw in the upper mounting screws at the position whished mount the head end station and mark the positio...

Страница 14: ...aeration e g by means of ventilators is to be ensured If the maximum ambient temperature inside the cabinet exceeds 50 C a thermo switch with reclose inhibition must auto matically disconnect the syst...

Страница 15: ...ket Fig 10 S S 3 Remove the fastening screws S of an unoccupied slot 3 from the bracket of the head end station Insert the cassette in this slot and push it into the housing Align the cassette accordi...

Страница 16: ...lity To comply with the current EMC regulations it is necessary to connect the lines leading in and out of the head end station e g Cinch RF using standard ca ble terminals Fig 12 According to figure...

Страница 17: ...ns connection Use only the mains cables supplied They are part of the approval and must only be replaced by an original spare part Fig 14 Connect both power supplies via the attached power cords to ma...

Страница 18: ...m tone sounds until the reset button is pressed Fig 14 page 17 In addition the following message is displayed POWER SUPPLY POWER WARNING If both power supplies are defective or switched off the follow...

Страница 19: ...the connectors Y of the power distributor Fig 15 The total output current for all LNBs connected must not exceed 1 A Fig 15 Y Connecting peripheral devices Via connector W Fig 2 page 9 peripheral devi...

Страница 20: ...20 STC 816 R 7 Setting the contrast of the display Adjust the contrast of the display using the controller...

Страница 21: ...values and trigger actions MULTI selects presets M saves all entries 8 2 Menu items The key pad on the head end station is used to scroll through the menus The two line display of the control unit the...

Страница 22: ...D SUB socket 9 pin D SUB plug 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 For PCs with USB connector without serial interface we recom mend the DeLOCK USB 2 0 to Serial adapter Product No 61460 Start the BE...

Страница 23: ...1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 k Switch on the head end station Wait for the Update Mode message of the master control unit and press button on this unit The software of the...

Страница 24: ...it to the 15 pin D SUB socket of the head end station Connect snap in hook in the direction opposite that of arrow 1 11 Programming 11 1 Preparation Connect the test receiver to the test output of th...

Страница 25: ...dB STATION 001 NUMBER BOX LEVEL LEVEL Bx 1 6 dB 0 25 dB 0 6 dB Bx 1 Bx 12 SYSTEM OFF MODEM ON OFF INFO V 1 SYSTEM Output Coll SYSTEM Clock INFO 14 7 MHz C F INFO 21 C SYSTEM Temp INFO 001 SYSTEM Stati...

Страница 26: ...ed A M B STATION 001 NUMBER SYSTEM OFF MODEM ON OFF SYSTEM PASSWORD SECURE 0000 Page 26 ATTENTION Temp 1 68 C A M SYSTEM MAX 68 C INFO 84 C INFO 21 C SYSTEM Temp Angezeigte Maximaltemperatur z B 68 C...

Страница 27: ...ny menu Any entries that have not been saved are reset to the previous settings Entries in the menus can be saved by pressing the key You are taken back to the Activating system information menu item...

Страница 28: ...re also can be called up from the stand by mode of the display System information control unit This menu shows the software version of the control unit e g V 45 SYSTEM BErem INFO V 45 Perform settings...

Страница 29: ...head end station Additionally the temperature display can be switched from degree Celsius to degree Fahren heit and the highest inner temperatures recorded to date can be displayed INFO 21 C SYSTEM Te...

Страница 30: ...unit The frequency can be 14 7 or 16 0 MHz SYSTEM Clock INFO 14 7 MHz Press the button The Setting the RF output level of the cassettes BOX LEVEL menu is activated Pressing the button you return to th...

Страница 31: ...he cable system STATION LEVEL LEVEL 3 dB Set the RF output level of the head end station using the buttons 0 6 dB Press the button The Setting the consecutive number of the head end station STATION NU...

Страница 32: ...g the buttons switch on the modem mode ON or if necessary switch it OFF If no modem is found NOT FOUND is displayed Press the button The Setting the password SYSTEM SECURE menu is activated Setting th...

Страница 33: ...he display instead of the BE Remote standby display In this operating state the menus for the cassettes and operating unit are locked To be able to access the menus for the cassettes and operating uni...

Страница 34: ...r and the software You can also select the current inner temperature SYSTEM MAX 68 C INFO 84 C INFO 21 C SYSTEM Temp Press the button to select the current inner temperature e g 21 C Press the button...

Страница 35: ...00 it is possible to check the condition of the power supplies and if necessary to switch off and on all cassettes of the station reset Establish a connection to the head end station via the PSW 1000...

Страница 36: ...tage is present via the sec ond power supply If Power ERROR is displayed both power supplies are defective switched off the station is out of order Restart the cassettes of a station reset Via the sup...

Страница 37: ...ler Access for this menu is only possible via this button The setting of the output level of cassettes is possible from the control units software version V44 BE Remote on Click to button an Adjust th...

Страница 38: ...the cable connections Cinch RF connectors using an ap propriate open ended spanner Hang the front cover into the mounting screws 2 Tighten the mounting screws Attach the locking screws 1 and tighten...

Страница 39: ...ner Stra e 43 D 90471 Nuremberg CLASS CLASS KLASSE KLASSE Phone 49 0 911 633 240 0 Fax 49 0 911 633 240 98 www gss de en info gss de Service Phone 49 0 911 633 240 90 service gss de Alterations reserv...