Raymarine DSM30 Скачать руководство пользователя страница 1

DSM300 & DSM30
Digital Sounder 
Module

Installation Manual

Document number: 87080-1
Date: November 2006

Содержание DSM30

Страница 1: ...DSM300 DSM30 Digital Sounder Module Installation Manual Document number 87080 1 Date November 2006...

Страница 2: ...stered trademarks HSB Raymarine and SeaTalk are registered trademarks of Raymarine plc All other product names are trademarks or registered trademarks of their respective owners Contents of this handb...

Страница 3: ...1 3 Selecting Sounder Module Mounting Location 10 1 4 Mounting the Sounder Module 11 1 5 Cable Runs 14 1 6 System Connections 14 Transducer Connection 15 DC Power Connection 15 Ground Connection 18 1...

Страница 4: ...the Internet 28 Customer Support 28 In the US 28 Accessories and Parts 28 Technical Support 29 Product Repair and Service 29 In Europe 30 Technical Support 30 Accessories and Parts 30 Worldwide Suppo...

Страница 5: ...rdance with the instructionscontainedinthismanual Failuretodosocanresultinpersonalinjury and or navigational inaccuracies In particular CAUTION High Voltage DigitalSounderModulescontainshighvoltages A...

Страница 6: ...isposal Waste Electrical and Electronic Equipment WEEE Directive The WEEE Directive requires the recycling of waste electrical and electronic equipment While the WEEE Directive does not apply to some...

Страница 7: ...equired to ensure that performanceisnotcompromised Althougheveryefforthasbeentakentoensure that they will perform under all conditions it is important to understand what factors could affect the opera...

Страница 8: ...avoided unless doing so is detailed in the installation manual If a suppression ferrite is attached to a cable this ferrite should not be removed Iftheferriteneedstoberemovedduringinstallationitmustb...

Страница 9: ...4 D9598 1 DSM300 Digital Sounder Module part no E63069 C Series Network Cable 3m part no E65010 hsb2 adapter 4 pin to 3 pin part no R69081 Operation Manual for PLUS Displays part no 81249 DSM300 Opera...

Страница 10: ...r above or below deck Mount the DSM where it is protected from physical damage and excessive vibration protected from prolonged exposure to rain salt spray and direct sunlight well ventilated as close...

Страница 11: ...ting CAUTION Do Not Remove the Transducer Cable Removing the transducer cable from the sounder module while power is turned on can cause sparks As with any electronic device be sure the sounder module...

Страница 12: ...Holdthemodule inthelocationwhereyouwanttomount it makingsureitis perpendicular to the deck 2 Mark the location of the four key holes onto the mounting surface 3 Drill a 9 64 pilot hole at each of the...

Страница 13: ...the marked location withan oversized bitand countersink toapproximately3 8 diame ter 4 Drivethesupplied 8screwsintothepilotholes Screwtheminabouthalfway 5 Mount the module to the surface slipping the...

Страница 14: ...place using tie wraps or lacing twine Coil any extra cable and tie it out of the way 1 6 System Connections The connector panel provides the following connection sockets T D 7 pin socket for connectin...

Страница 15: ...a DC power distribution panel Power should be fed directlytotheDSMviaitsowndedicatedcablesystemandprotectedbyathermal circuitbreakerorfuseonthered positive wirethatisinstalledclosetothepower connectio...

Страница 16: ...powercord canbeeasily removed if necessary If the sounder is placedin adifficult to reachlocation Raymarine strongly suggests installing an on off switch onthe DSM power cord ata pointwhere itis easil...

Страница 17: ...Connections with a C Series Display Power Connections with an hsb2 PLUS Series Display D9601 1 Transducer Sounder Module C Series Display Unit Power Supply D9602 1 Transducer Sounder Module hsb PLUS...

Страница 18: ...ry terminal connected to the boat s ground This system is not intended for use on positive ground vessels 1 7 Display Configuration The DSM must be connected to an hsb2 PLUS Series C Series or E Serie...

Страница 19: ...3m long C Series cable is included with your sounder module and is also available in a 10 m length Raymarine part number E65011 The display cable attaches to the 4 pin male connector labelled HSB2 on...

Страница 20: ...DSM however is internally terminated it does not require an inline terminator Because the sounder module is internally terminated it must be installedattheendofthehsb2 network Youmustnotuseaninline t...

Страница 21: ...module is a sealed unit Maintenance procedures are therefore limited to the following periodic checks Examine the cables for signs of damage such as chafing cuts or nicks Check that the cable connect...

Страница 22: ...rvice procedures and replacement parts used will not affect performance There are no user serviceable parts in any Raymarine product Some products generate high voltages so never handle the cables con...

Страница 23: ...SM Reset 5 Scroll to Reset DSM 6 To confirm the reset select YES i The power on the DSM cycles OFF and ON ii The introductory logo is displayed iii After a few seconds an application page and a naviga...

Страница 24: ...play The reset is complete To cancel the reset Before pressing YES as described in item 4 above press any of the following keys DISPLAY MULTI VRM EBL MARKS RANGE GAIN or ALARMS This action opens up a...

Страница 25: ...ducer must be replaced as a unit Sounder does not display fish 1 Fish arches are not displayed if the boat is stopped fish appear on the display as straight line 2 Ensure the transducer is within 10 o...

Страница 26: ...LED blinks green once every 10 seconds For example if the Transducer Sense fails and the network is not detected the LED blinks amber once pauses 1 5 secs blinks amber twice 0 5 secs apart pauses 1 5...

Страница 27: ...le to attempt to self correct the condition If the condition persists please contact Raymarine Customer Service Table 2 3 Status LED Error Indications Color No of blinks Meaning Cleared every 10 min R...

Страница 28: ...uct category keywords or phrases If the answer you are seeking is not available click the Ask Raymarine tab to submit your own question to our technical support staff who will reply to you by e mail I...

Страница 29: ...rine dealer for assistance The dealer is best equipped to handle your service requirements and can offer timesaving help in getting the equipment back into normal operation In the event that repairs c...

Страница 30: ...chnical helpdesk contact Tel 44 0 23 9271 4713 Fax 44 0 23 9266 1228 Accessories and Parts Raymarine accessory items and parts are available through your authorized Raymarine dealer Please refer to th...

Страница 31: ...mmended Environmental Operating Range Storage Range Humidity Waterproof to IPX 7 10 C to 50 C 20 C to 70 C up to 95 at 35 C non condensing Connectors 7 pin transducer 4 pin hsb2 input output 3 pin pow...

Страница 32: ...32 DSM300 and DSM30 Installation Manual...

Страница 33: ...Servicing Safety Guidelines 22 Error codes 26 F Factory Reset 23 G Ground Connections 18 H Help from Raymarine 28 High Voltage 5 HSB2 Connector 14 hsb2 PLUS Series displays Connections 17 20 I Instal...

Страница 34: ...34 DSM300 and DSM30 Installation Manual Transducer Cleaning 21 Connections 14 15 W Warning codes 26 Warranty 6...

Отзывы: