GDV 200
Service Test Programme
GRUNDIG Service
2 - 9
ķ
GB
Service Test Programme
The Service Test Programme is divided into 3 different parts:
– Automatic System Test
– Manual System Test
– PC System Test
The basis of these System Tests are the Service Test Levels, which are
carried out automatically with the respective test or can be called up
manually.
The keys illustrated below are located on the left side of the magnetically
fixed cover.
2. Manual System Test
The Manual System Test is a possibility to check which of the modules
(Keyboard Control Unit, DVD Monoboard or Drive Mechanism) is
faulty. In addition to that, it is possible to check all ERRORS by reading
the ERROR log and the ERROR bits, including the ERRORS which
have appeared in the normal use of the DVD-Player. At the end of the
Manual System Test a Loop Test is started (the Service Test Levels of
the Automatic System Test are running in an endless loop).
For this test the DVD-Player has to be connected to a TV Set (PAL or
Multisystem), to control the results of the Service Test Levels.
To check the results of some Service Test Levels, the System Test
requires interactive actions from the user (e.g. confirmation of a
testpicture or a testsound). For some levels (e.g. levels for testing the
Drive Mechanism functions) the DVD-Player has to be opened to
control the function of the moveable components.
The test only checks functions, which can be checked by the Service
Test Software.
Start of the Manual System Test
Press 2 keys simultaneously
<OPEN/CLOSE> + <STOP>
Switch power ON
Disconnect the VCR from
the mains to end player test
Keyboard Control Unit
DVD Monoboard
Display Test
Interactive Test
LED Test
Keyboard Test
Remote Control Test
Picture Test 1
Basic Engine
Version Number
Tray Test
Sledge Test
Disc Motor Test
Focus Test
Radial Test
Jump Test
Tray Test
Error Log & -Bits
Loop Test
30 (DispDisplay)
29 (DispLed)
27 (DispKeyb)
28 (DispRc)
37 (BeVer)
43a/b (BeTrayOut/In)
20a (AudioPinkNoiseOn)
54a (VideoScartSwDvd)
23a (VideoColDencOn/Off)
41a/b (BeSledgeOut/In)
39a (BeDiscMotorOn)
38a (BeFocusOn)
40a (BeRadialOn)
42a/b/c (BeGroovesIn/Mid/Out)
43a/b (BeTrayOut/In)
31 (LogReadErr)
32 (LogReadbits)
Sound Test 1 / DVD-EURO-AV Test
54b (VideoScartSwPass)
EURO-AV Loop Test
AudioSinOn
Sound Test 2
53a (VideoColSetupHi)
53b (VideoColSetupLo)
Colour Setup Test
2.1 Interactive Tests
2.1.1 Keyboard Control Unit
Display Test
Service Test Level: DispDisplay
By showing a series of test patterns on the local display, the local
display is tested. To step through all different patterns, the user must
either press PLAY (pattern is OK) or PAUSE (pattern was incorrect) to
proceed to the next pattern. The display of patterns is continued
cyclically manner until the user presses NEXT.
Note that a different sample pattern is used here to show all different
display patterns. All other pattern in this document are simplified for
essentials.
If the user presses NEXT before all display patterns are tested, it will
cause an error in the overall result of the System Test.
1. Automatic System Test
With the Automatic System Test the hardware of the DVD-Player can
be checked without further equipment.
During the Automatic System Test the Service Test Levels, which are
listed in the table, are called and executed. If the DVD-Player is faulty,
"Error" is shown on the display and the Service Test Levels have to be
executed with the Manual System Test or the PC System Test.
Start of the Automatic System Test
Press 2 keys simultaneously
<OPEN/CLOSE> + <PAUSE>
Connect to mains
SET OK
During the test, the display shows
the number of Levels
which have to be tested.
To exit Automatic Systemtest: disconnect the VCR from the mains
NO
YES
VCD
D
SHUFFLE
CHAPTER
TRACK
SCAN
A-B
FTS
TOTAL
TRACK
TRACK
TITLE
TIME
CHAPTER
VD
TITLE
W
REPEAT
L
DIGITAL
SURROUND
L
R
C
R
S
S
S
VCD
D
SHUFFLE
CHAPTER
TRACK
SCAN
A-B
FTS
TOTAL
TRACK
TRACK
TITLE
TIME
CHAPTER
VD
TITLE
W
REPEAT
L
DIGITAL
SURROUND
L
R
C
R
S
S
S
VCD
D
SHUFFLE
CHAPTER
TRACK
SCAN
A-B
FTS
TOTAL
TRACK
TRACK
TITLE
TIME
CHAPTER
VD
TITLE
W
REPEAT
L
DIGITAL
SURROUND
L
R
C
R
S
S
S
Nucleus
Description
Checks the I
2
C interface with the
IC7316 on the AV-MUX Board
Checks the I
2
C interface with the
IC7305 on the AV-MUX Board
Calculate and verify checksum
FLASH memory
VideoColSetupComm
VideoScartSwComm
PapChksFl
Number
on
display
9
8
7
Pattern test of all locations in the DRAM(s)
Checks the I
2
C interface with the
slave processor on the display PCB
Checks the I
2
C interface to the
drive mechanism
PapDramWrR
Papl2cDisp
PapS2bEcho
6
5
4
Checks the I
2
C interface with the NVRAM
Pattern test of all locations in the NVDRAM
Pattern test of all locations in the
SDRAM(s)
Papl2cNvram
PapNvramWrR
CompSdramWrR
3
2
1
Pause (3)
Previous (2)
Next (1)
Stop (4)
Open / Close (5)
Play (0)