background image

1

Green Ground

Neutral

Line

CAP

A

CIT

OR

2 3 4 5 6 7 8

6

Start-Up

Do not use the pump to vent the system. Do not start the 

pump before filling the system. Never operate the pump dry.

Operation

GRUNDFOS domestic circulating pumps, installed properly and 

sized for correct performance, will operate quietly and efficiently 

and provide years of service. Under no circumstances should 

the pump be operated without water circulation or without the 

minimum required inlet pressure for prolonged periods of time.  This 

could result in motor and pump damage.UPS model pumps are 

multispeed, and the speed can be changed by a speed selector 

switch located on the front of the terminal box. UP models are 

single speed.

Failure to Operate

When UPS 15-42 and UPS 26/43 pumps are first started, the shaft 

may rotate slowly until water has fully penetrated the bearings. 

If the pump does not run, the shaft can be rotated manually. To 

accomplish this, switch off the electrical supply, and close the 

isolation valves on each side of the pump. Remove the indicator 

plug  in  the  middle  of the  nameplate.   Insert a  small  flat blade 

screwdriver into the end of the shaft, and gently turn until the shaft 

moves freely. Replace and tighten the plug. Open the isolation 

valves and wait 2 to 3 minutes for the system pressure to equalize 

before starting the pump.
NOTE:  After a long shut down multi-speed pumps should be 

started on speed 3 and then adjusted to the regular setting. The 

UPS 15-42 has automatic function to assist in restart.

*IMPORTANT NOTE*:  For figure 1, the cap plug has not been 

installed. This pump is supplied with two wiring 

ports. To 

ensure safe operation of your installation, the enclosed cap plug 

MUST be inserted into the unused port.

*UP(S) 15 capacitor wire position 4 & 8  *UP(S) 26/43/50 

capacitor wire position 2 & 4

Wiring diagram for 

115V and 230V 

multi-speed pumps

Figure 2

Green Ground

Neutral

Line

Wire the hot lead to terminal "L," neutral wire to terminal "N," and 

ground to the grounding terminal.  For 230 volt pumps, the two hot 

leads should be to "L" and "N" and the ground to the grounding 

terminal.

 

   Limited Warranty

Содержание UPS 15

Страница 1: ...n and operating instructions Shipment Inspection 2 Pre Installation Checklist 2 Installation 3 Electrical 4 Start Up 5 Operation 6 Failure to Operate 6 Warranty 7 CONTENTS GRUNDFOS INSTRUCTIONS UP Series circulators ...

Страница 2: ...due to an increase in the viscosity of the solution Check with manufacturer for information regarding suitability of pumping other fluids Closed Systems Model UP S 15 26 43 and 50 series pumps with cast iron pump housings are designed to pump water compatible with their cast iron construction They are recommended for use in closed hydronic systems i e airless non potable water Open Systems Model U...

Страница 3: ... box position needs to be changed it is best to do so before installation However if the pump is already installed ensure that the electrical supply is turned off and close the isolation valves before removing the Allen screws To change terminal box position 1 Remove the four 4 Allen screws 4 or 5mm wrench while supporting the stator motor 2 Carefully separate the stator from the pump chamber and ...

Страница 4: ...he lowest point of the system where dirt and sediment naturally collect 3 Install an air vent at the high point s of the system to remove accumulated air 4 Ensure that water does not enter the terminal box during the installation process 5 Open System Install the pump in the supply line the suction side of the pump should be flooded with water Ensure that the static head requirement from Table 2B ...

Страница 5: ...plate attached to the top of the motor Depending on pump model the motor has either built in automatic resetting thermal protection or is impedance protected and in either case does not require additional external protection The temperature of the windings will never exceed allowable limits even if the rotor is locked Wire sizes should be based on the ampacity current carrying properties of a cond...

Страница 6: ...e electrical supply and close the isolation valves on each side of the pump Remove the indicator plug in the middle of the nameplate Insert a small flat blade screwdriver into the end of the shaft and gently turn until the shaft moves freely Replace and tighten the plug Open the isolation valves and wait 2 to 3 minutes for the system pressure to equalize before starting the pump NOTE After a long ...

Страница 7: ...s and not by GRUNDFOS warranty GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating conditions accident abuse misuse unauthorized alteration or repair or if the product was not installed in accordance with GRUNDFOS printed installation and operation instructions To obtain service under this warranty the defective product must be returned to the distributor or dea...

Страница 8: ... Grundfos Canada Inc 2941 Brighton Rd Oakville Ontario L6H 6C9 Telephone 905 829 9533 Fax 905 829 9512 Bombas Grundfos de Mexico S A de C V Boulevard TLC 15 Parque Industrial Stiva Aeropuerto C P 66600 Apodaca N L Mexico Telephone 52 81 8144 4000 Fax 52 81 8144 4010 L UP TL 053 06 11 Repl 06 07 PRINTED IN USA ...

Отзывы: