6.3 Service kits
The impeller, the inlet strainer and the non-return valve are
replaceable.
Order numbers for the ordering of service kits and contents of
service kits appear from the tables below and fig. Service parts.
Pump type
Part number
Impeller kit
UNILIFT KP 150
UNILIFT KP 250
UNILIFT KP 350
015778
015779
015787
Inlet strainer
UNILIFT KP 150
UNILIFT KP 250
96548064
UNILIFT KP 350
96548066
Non-return valve
UNILIFT KP 150
UNILIFT KP 250
UNILIFT KP 350
15220
Service kits
Pos.
Designation
Quantity
Impeller kit
A
Impeller
1
B
Nut
1
C
Sealing part
1
Inlet strainer
D
Inlet strainer
1
D
C
B
A
TM031
166
Service parts
If other pump components are damaged or defective, contact the
pump supplier.
6.4 Contaminated pumps
If the power cable or the level switch is damaged, it must
be replaced by a service workshop authorised by Grund-
fos.
CAUTION
Biological hazard
Minor or moderate personal injury
‐
Flush the product thoroughly with clean water and
rinse the parts in water after dismantling.
‐
Wear personal protective equipment.
The product will be classified as contaminated if it has been used
for a liquid which is injurious to health or toxic.
If you request Grundfos to service the product, contact Grundfos
with details about the pumped liquid before returning the product for
service. Otherwise, Grundfos can refuse to accept the product for
service.
Any application for service must include details about the pumped
liquid.
Clean the product in the best possible way before you return it.
Costs of returning the product are to be paid by the customer.
15