6 / 8
4.4 Replacing the supply cable or float switch
1. Remove the motor, see
4.1 Removing the motor
.
2. Cut the defective cable and the cable entry just above the motor sleeve (pos. 55).
3. Cut off the wire connectors.
4. Pull the cable and cable relief (pos. 250a) out of the motor sleeve from the inside.
5. Push the cable entry out of the motor sleeve (pos. 55) from outside and in.
6. Lead the cable through the motor sleeve, and moisten the cable entry with water and fit it with the thin end
upwards. The cable entry must be approx. 20 cm from the cable end.
Note:
The cable entry for H05 cable is red, that for H07 white.
7. Fit the cable relief (pos. 250a) and pull the cable entry into position in the motor sleeve. The cable entry must now
be fixed in the retainer in the motor sleeve. It must not be possible to pull the cable any longer. The cable entry is
fitted correctly when its collar is free of the motor sleeve.
8. Strip the cable and fit the conductors with new wire connectors, see
Fig. 4. Wiring diagram
.
9. Fit the motor, see
4.5 Fitting the motor
.
4.5 Fitting the motor
1. Fit the O-ring (pos. 48a) on the motor and place the motor in the motor sleeve (pos. 55).
2. Fit the O-ring (pos. 37) on the pump sleeve (pos. 55a).
3. Fit the pump sleeve on the motor sleeve.
4. Fit and tighten the three screws (pos. 36).
5. Fit the diaphragm (pos. 58).
6. Fit the O-ring (pos. 37) on the bottom part (pos. 50).
7. Fit the bottom part to the pump sleeve.
8. Fit and tighten the three screws (pos. 84b).
9. Fit the strainer (pos. 84).
Содержание Unilift CC 5 M1