background image

4 / 8

3. Cleaning the pump

3.1 Cleaning the suction strainer

1. Drain the pump.

2. Loosen the strainer (pos. 84) by inserting a screwdriver between the bottom part (pos. 50) and the suction strainer 

and turning the screwdriver.

Fig. 1. 

Removing the suction strainer

3. Clean and refit the suction strainer.

3.2 Cleaning the impeller

1. Loosen the strainer (pos. 84) by inserting a screwdriver between the bottom part (pos. 50) and the suction strainer 

and turning the screwdriver.

2. Remove the screws (pos. 84b) and the bottom part (pos. 50).

Fig. 2. 

Removing the bottom part

3. Remove and clean the O-ring (pos. 37a) and the diaphragm (pos. 58).

4. Flush the inside of the pump between the motor and pump sleeve, and clean the impeller. Check that the impeller 

(pos. 49) can rotate freely and is intact.

5. Fit the diaphragm, O-ring and bottom part.

6. Fit and tighten the screws.

7. Press the suction strainer onto the pump.

Switch off the electricity supply before dismantling the pump.

TM

03

 0

8

31

 05

05

T

M

0

3

 1

1

12

 10

05

Содержание Unilift CC 5 M1

Страница 1: ...t finding 3 3 Cleaning the pump 4 3 1 Cleaning the suction strainer 4 3 2 Cleaning the impeller 4 4 Dismantling and assembly 5 4 1 Removing the motor 5 4 2 Replacing the capacitor 5 4 3 Replacing the...

Страница 2: ...11 Approvals 5 Product number 12 Motor input power 6 Production code 13 Maximum installation depth 7 Full load current 14 Supply voltage Example Unilift CC 7 A1 Pump range Type Maximum head m Operati...

Страница 3: ...nt cooling b Pump partly blocked by impurities or blocked Clean the pump see 3 2 Cleaning the impeller c Water level too low when the pump is started The pump cannot self prime Move the pump to a posi...

Страница 4: ...he bottom part pos 50 and the suction strainer and turning the screwdriver 2 Remove the screws pos 84b and the bottom part pos 50 Fig 2 Removing the bottom part 3 Remove and clean the O ring pos 37a a...

Страница 5: ...g 3 Removing the bottom part 3 Remove the O ring pos 37a and the diaphragm pos 58 4 Remove the screws pos 36 5 Remove the pump sleeve pos 55a by holding the sleeve and pressing the impeller 6 Moisten...

Страница 6: ...50a and pull the cable entry into position in the motor sleeve The cable entry must now be fixed in the retainer in the motor sleeve It must not be possible to pull the cable any longer The cable entr...

Страница 7: ...upwards during the measurement Fig 4 Wiring diagram Pump type Winding resistancea 10 a The table values do not include the cable Resistance in cable 2 x 10 m approx 1 Auxiliary winding Main winding Un...

Страница 8: ...8 8 6 Drawing TM03 1101 1005...

Отзывы: