6. Installation
During installation, the pump must only be lifted when using the
suspension point.
The lifting equipment supplied with the pump as well as the cable
used for lifting and lowering the pump into the tank must not be
used as universal lifting equipment.
6.1 Positioning
Correct positioning of the pump is essential to ensure trouble-free
operation and long life. The following guidelines must be
observed.
•
If more than one pumps is installed in the same tank,
they must not generate opposite flows, meaning that different
inlets/outlets should not destroy the general flow.
•
The distance from the center of the pump to the tank bottom
(H
min
) must notbe less than the propeller diameter. See fig. 3.
•
The distance from the top of the pump rack to the liquid
surface (H
ABOVE
) must fulfil one of the following two
requirements:
– For pumps with vortex shield, the distance must at least be
equal to the propeller diameter.
– For pumps without vortex shield, the distance must at least
be equal to 1.5 times the propeller diameter. See fig. 3.
Fig. 3
Distance to liquid surface and tank bottom
Fig. 4
Open installation
* Guide claws are only available for SRP.xx.32.
Caution
Never hang the pump by the power cable.
Never let the pump run while hanging by the
lifting equipment.
Note
Note
Actual mounting assemblies supplied locally may
differ slightly from the detailed assembly
described although functionality will be
maintained
T
M
02
94
78
27
04
H
min
H
Above
T
M
04
39
62
05
0
9
Pos.
Designation
1
Bottom mounting bracket and guide claws on
connection flange *
2
Guide rail
4
Pump rack
5
Top mounting bracket
12
Crane foot
13
Crane with winch and lifting cable
15
Lifting cable incl. cable clamp
17
Cable clamp
18
Cable sock, incl. shackle
10
19
Intermediate mounting bracket
23
Connection flange
13
5
17
15
23
1
1
2
19
12
18