English (GB)
5
2. Storage and handling
2.1 Storage
•
Observe the permissible ambient conditions. See
section
4. Technical data / Dimensions
.
•
The storage location must be protected from rain,
humidity, condensation, direct sunlight and dust.
•
The product must be drained completely.
•
The product must be cleaned.
2.2 Unpacking
•
Mount as soon as possible after unpacking.
•
Observe the permissible ambient conditions. See
section
4. Technical data / Dimensions
.
2.3 Transport
•
The product must only be transported by trained
persons.
•
Wear personal protective equipment.
•
Observe the permissible ambient conditions. See
section
4. Technical data / Dimensions
.
•
The product must be drained completely.
•
The product must be cleaned.
•
Use the original packaging or equivalent to
protect the product during transport.
•
Use appropriate lifting and transporting devices.
•
Secure the product during transport to prevent it
from tilting and moving.
•
Avoid strong impact loads.
•
If the pump is installed in a system during
transport, make sure it is secured on the
mounting plate with the 6 vertical safety screws.
See section
5.1.3 Installing the pump on the
3. Product introduction
The DDE dosing pump is a self-priming diaphragm
pump. It consists of a housing with PMS (Permanent
Magnet Synchronous) motor and electronics, a
dosing head with double PTFE diaphragm and
valves and the control cube.
Excellent dosing features of the pump:
•
Optimal intake even with degassing media, as
the pump always works at full suction stroke
volume.
•
Continuous dosing, as the medium is sucked up
with a short suction stroke, regardless of the
current dosing flow, and dosed with the longest
possible dosing stroke.
3.1 Applications
The pump is suitable for liquid, non-abrasive,
non-flammable and non-combustible media.
Observe the technical data of the product. See
section
.
Observe the freezing and boiling points of the dosing
medium.
Make sure that parts in contact with the dosing
medium are resistant to the dosing medium under
operating conditions. See data booklet:
•
http://net.grundfos.com/qr/i/99021865.
Should you have any questions regarding the
material resistance and suitability of the pump for
specific dosing media, please contact Grundfos.
A sunscreen is required for outdoor installation.
Areas of application
•
Drinking water treatment
•
Wastewater treatment
•
Boiler water treatment
•
Cooling water treatment
•
Process water treatment
•
CIP (Clean-In-Place). Observe section
4.2 Technical data for CIP (Clean-In-Place)
applications
.
•
Swimming pool water treatment
•
Chemical industry
•
Ultrafiltration process and reverse osmosis
•
Food and beverage industry
•
Paper and pulp industry
•
Irrigation.
3.2 Improper operating methods
The operational safety of the pump is only
guaranteed if it is used in accordance with section
Other applications or the operation of pumps in
ambient and operating conditions, which are not
approved, are considered improper and are not
permitted. Grundfos cannot be held liable for any
damage resulting from incorrect use.
The pump is NOT approved for operation
in potentially explosive areas, automotive
applications or marine applications.
Only use the deaeration valve for
deaerating the pump. Make sure the
deaeration valve is closed during normal
operation.