Disch. valve leak
(Warning)
• Leaky/dirty outlet valve. Dosing
medium flows back from the outlet
line into the dosing head which
reduces the target flow.
• Check valve and tighten it up. Replace
valve if necessary. See section
• Flush system.
• Check O-ring position.
• Install strainer in inlet line.
• Install spring-loaded valve on the outlet
side.
Overload
(Alarm)
• Backpressure exceeds max.
operating pressure
• Reduce backpressure. Observe section
• Outlet valve blocked
• Isolating valve in outlet line closed
• Replace valve if necessary. See section
• Check flow direction of valves (arrow) and
correct if necessary.
• Open the isolating valve (on the outlet
side).
• Pressure peaks
• Enlarge diameter of outlet line.
• Install a pulsation damper in the outlet line
close to the outlet valve.
• Ambient temperature below
specified minimum value. See
section
.
• Adjust ambient temperature to specified
value.
Pressure sensor
(Warning)
• Broken "
FlowControl
" cable or
sensor (see fig.
)
• Check plug connection.
• Replace dosing head with sensor if
necessary.
• If the "Flow control" connection at the
pump is damaged, send the pump for
repair. See section
Motor blocked
(Alarm)
• Backpressure greater than
nominal pressure
• Reduce backpressure.
• Incorrectly installed diaphragm
• Install the diaphragm correctly.
• Damage to gears
• Hall sensor failure
• Motor failure
• Contact your Grundfos service partner.
Bus error
(Alarm)
• Fieldbus communication error
• Check cables for correct specification and
damage; replace if necessary.
• Check cable routing and shielding; correct
if necessary.
CIU
(Alarm)
• CIU connection error
• Check plug connection.
• Faulty CIU
• Replace CIU if necessary.
Sensor signal
(Alarm)
• Sensor signal out of range 0/4-20
mA
• Check cable/plug connections and
replace, if necessary.
• Check signal transmitter.
Stop after power
failure
(Alarm)
• Function "
Stop after power failure
"
is enabled and power supply was
switched on or reestablished after
power failure.
• Check power supply and mains cable.
• Read section
Diaphragm leak.
(Alarm)
• Diaphragm leakage
• Read section
• Change the diaphragm. See section
Display in the
"
Alarm
" menu
Possible cause
Possible remedy