E
ngl
ish (
G
B)
9
3. Technical data / dimensions
3.1 Technical data
Data
DDA pump type
7.5 - 16
12-10
17-7
30-4
Mechanical
data
Turndown ration (setting range)
[1:X]
3000
1000
1000
1000
Max. dosing flow
[l/h]
7.5
12.0
17.0
30.0
[gph]
2.0
3.1
4.5
8.0
Max. dosing flow with SlowMode 50 %
[l/h]
3.75
6.00
8.50
15.00
[gph]
1.00
1.55
2.25
4.00
Max. dosing flow with SlowMode 25 %
[l/h]
1.88
3.00
4.25
7.50
[gph]
0.50
0.78
1.13
2.00
Min. dosing flow
[l/h]
0.0025
0.0120 0.0170
0.0300
[gph]
0.0007
0.0031 0.0045
0.0080
Max. operating pressure
[bar]
16
10
7
4
[psi]
230
150
100
60
Max. stroke frequency
1)
[Strokes/
min]
190
155
205
180
Stroke volume
[ml]
0.74
1.45
1.55
3.10
Accuracy of repeatability
[%]
±1
Max. suction lift during operation
2)
[m]
6
Max. suction lift when priming with wet
valves
2)
[m]
2
3
3
2
Min. pressure difference between suction
and discharge side
[bar]
1 (FC and FCM: 2)
Max. pressure, suction side
[bar]
2
Max. viscosity in SlowMode 25 % with
spring-loaded valves
3)
[mPa s]
(= cP)
2500
2500
2000
1500
Max. viscosity in SlowMode 50 % with
spring-loaded valves
3)
[mPa s]
(= cP)
1800
1300
1300
600
Max. viscosity without SlowMode with
spring-loaded valves
3)
[mPa s]
(= cP)
600
500
500
200
Max. viscosity without spring-loaded
valves
3)
[mPa s]
(= cP)
50
300
300
150
Min. diameter of hose/pipe on suction/
discharge side
2) 4)
[mm]
4
6
6
9
Min. diameter of hose/pipe on suction
side for highly viscous media (HV)
4)
[mm]
9
Min. diameter of hose/pipe on discharge
side for highly viscous media (HV)
4)
[mm]
9
Max. media temperature
[°C]
45
Min. media temperature
[°C]
-10
Max. ambient temperature
[°C]
45
Min. ambient temperature
[°C]
0
Max. storage temperature
[°C]
70
Min. storage temperature
[°C]
-20
Содержание SMART Digital DDA