English (GB)
12
11. Dismantling and assembling the product
General information
Position numbers of parts (digits) refer to section
.
Position numbers of tools (letters) refer to section
Before dismantling the product
• Switch off the power supply.
• Close the isolating valves, if fitted, to avoid draining the piping
system.
• Disconnect the power supply cable in accordance with local
regulations.
• Note the centre of gravity of the pump to prevent it from
overturning.
11.1 Dismantling the product
11.1.1 Draining the motor oil
See section
10.3 Checking and changing the motor oil
11.1.2 Removing the grinder system
1. See section
2. Place the pump horizontally on the table.
3. Loosen and remove the screw (188a) in one of the pump feet.
4. Loosen the grinder ring (44) by knocking it clockwise with a
punch (
). See fig.
Fig. 9
Dismantling the grinder ring
5. Gently remove the grinder ring (44) from the pump housing
using a screwdriver (
6. Insert the punch (
) into the hole to hold the impeller to
prevent it from moving during dismantling.
7. Remove the screw (188a) from the shaft end. Remove the
locking ring (66). See fig.
Fig. 10
Dismantling the screw and grinder head
8. Remove the grinder head (45).
11.1.3 Removing the pump housing
1. See section
11.1.2 Removing the grinder system
.
2. Place the pump vertically.
3. Support the pump from the lifting bracket (190) with a hoist.
4. Loosen the clamp (92) holding the pump housing (50) and
stator housing (55) together.
5. Lift the pump housing (50) off the stator housing (55) including
the O-ring (37) and the impeller (49). Place the pump
horizontally.
6. Clean the pump housing (50).
11.1.4 Removing the impeller
1. See section
11.1.3 Removing the pump housing
2. Insert the punch (
) in the impeller (49) to prevent it from
moving during dismantling.
3. Remove the adjusting nut (68).
4. Fit the puller (
) on the shaft. See fig.
.
Fig. 11
Fitting the puller on the impeller
5. Fit the M8 screw in the puller and pull out the impeller (49).
6. Remove the key (9a).
7. Clean the shaft and key.
DANGER
Sharp element
Death or serious personal injury
- Be careful of the sharp edges on the impeller,
grinder head and grinder ring.
TM0
6
575
6 01
16
Make sure that the grinder ring does not get stuck
against the grinder head.
TM
06 57
47 01
16
Clean the pump housing. Grind the surfaces slightly
with emery cloth, if necessary.
CAUTION
Sharp element
Minor or moderate personal injury
- Be careful of the sharp edges on the impeller and
the grinder head.
TM
04
69
69
18
10
Clean the impeller. Grind the surfaces slightly with
emery cloth, if necessary.
Содержание seg autoadapt
Страница 1: ...SEG AUTOAdapt 0 9 4 0 kW DIN 50 Hz Service instructions GRUNDFOS INSTRUCTIONS ...
Страница 19: ...English GB 19 13 Drawings 13 1 Sectional drawing 0 9 to 1 5 kW TM06 6109 0716 6a Single phase pump only ...
Страница 20: ...English GB 20 13 2 Exploded view 0 9 to 1 5 kW TM06 5750 0316 ...
Страница 21: ...English GB 21 13 3 Sectional drawing 2 6 to 4 0 kW TM06 6111 0716 6a ...
Страница 22: ...English GB 22 13 4 Exploded view 2 6 to 4 0 kW Fig 21 SEG AUTOADAPT 2 6 4 kW TM06 5770 0316 ...