No
Message
Description
Check/Repair
Necessary device options
for this message
E12
El2:transmitter PLlo
meas.signa1 too high
Measurement signal of
pressure transmitter PL1o
(vessel pressure top) is
above the normal
valid range.
- connection from pressure
transmitter PL1o incorrect
or damaged
- pressure transmitter defect
- measure input of basic
circuit board defect
no (contained in every
configuration
E13
El3:transmitter PLlo
meas.signa1 too 1ow
Measurement signal of
pressure transmitter PL1o
(vessel pressure top) is
below the normal
valid range.
- pressure transmitter PL1o
is disconnected
- connection from pressure
transmitter is incorrect
or damaged
- pressure transmitter
is defective
- measure input of basic
circuit board is defective
no (contained in every
configuration)
E14
El4:transmitter PLlu
meas.signa1 too high
Measurement signal of
pressure transmitter PL1u
(vessel pressure bottom) is
above the normal
valid range.
- connection of pressure
transmitter PL1u is
incorrect or damaged
- pressure transmitter is
defective
- measure input of basic
circuit board is defective
no (contained in every
configuration)
E15
El5:transmitter PLlu
meas.signa1 too 1ow
Measurement signal of
pressure transmitter PL1u
(vessel pressure bottom) is
below the normal
valid range.
- pressure transmitter PL1u
is disconnected
- connection from pressure
transmitter is incorrect
or damaged
- pressure transmitter
is defective
- measure input of basic
circuit board is defective
no (contained in every
configuration)
E16
E16: dr’= run Protec.
has been activated
Dry run protection for
pressure maintenance pump
has been activated for at
least one time.
This message could appear
if fresh water supply is
closed, back feed module is
defect, makeup amount is
exceeded, Refill outstripping
infill, etc.
After reaching the minimum
level the function of the
device will be enabled
automatically. The message
must be reset manually
no (contained in every
configuration)
38
Содержание PHP A-1 4.0
Страница 1: ...PHP A 1 4 0 5 6 6 6 8 1 Instruction manual UK version original instructions...
Страница 5: ...PHP A 1 Instruction Manual Mounting 05 Figure 1 Changing the positions of the hydraulic connections...
Страница 12: ...PHP A 1 Instruction Manual Wiring diagrams 4 Wiring diagrams 12 4 1...
Страница 13: ...PHP A 1 Instruction Manual Wiring diagrams 13...
Страница 14: ...PHP A 1 Instruction Manual Wiring diagrams 14...
Страница 51: ...PHP A 1 Instruction Manual Appendix 51...
Страница 52: ...PHP A 1 Instruction Manual EC declaration of Conformity 52 13 EC declaration of Conformity...