6. Start-up

Note:

 Do not start the pump until it has been filled with liquid and vented.

6.1 Priming

The suction pipe and the pump must be filled with liquid and vented before the pump is started.

If the liquid level is below the pump inlet or there are airlocks in the suction pipe, proceed as follows:

1. Close the discharge isolating valve and open the isolating valve in the suction pipe.

2. Loosen the air vent screw (pos. 17).

3. Remove the plug (pos. 20) from one of the pump flanges, depending on the pump location.

4. Pour liquid through the priming hole.

5. Make sure the suction pipe and the pump are completely filled with liquid.

6. Fit the plug and tighten securely.

7. Tighten the air vent screw (pos. 17).

The suction pipe can to some extent be filled with liquid and vented before it is connected to the pump. A priming device can 
also be installed before the pump.

6.2 Checking the direction of rotation

Note:

 The pump must be filled with liquid when checking the direction of rotation. 

The correct direction of rotation is indicated by the arrow on the pump housing. When seen from the motor fan, the pump should 
rotate clockwise. Start the motor only for a short moment.

6.3 Start-up

1. Completely open the suction isolating valve and leave the discharge isolating valve almost closed.

2. Start the pump.

Note:

 Sudden, large pressure changes in the discharge pipe may damage the pump.

3. Vent the pump during starting by loosening the air vent screw (pos. 17) in the pump head until a steady stream of liquid runs 

out of the vent hole.

4. When the piping system has been filled with liquid, slowly open the discharge isolating valve until it is completely open.

5. In case of overload, throttle the valve on the discharge side until the motor is not overloaded.

6. If the pump does not build up pressure at once, stop it and repeat the starting procedure.

6.4 Restarting

Do not restart the pump until the pump shaft stands still.

6.5 Stopping

Backflow is stopped by means of the non-return valve or counter pressure in the pipeline.

Switch off the motor and check that it slows down smoothly.

Fit the coupling guard before starting the pump.

In hot-water installations, special attention should be paid to the risk of personal injury caused by scalding hot water.

The motor should not be removed when checking the direction of rotation, as this may damage the shaft seal.

Pay attention to the orientation of the vent hole to ensure that the escaping water does not cause personal injury or 
damage to the motor or other components.

In hot-water installations, special attention should be paid to the risk of personal injury caused by scalding hot water.

The pump must never be operated for long periods if the isolating valve on the discharge side is closed.

Backflow of the pumped liquid must not result in a change in the direction of rotation of the pump.

Содержание MTB 50-200/215

Страница 1: ...the impeller 6 4 4 Removing the shaft seal and pump head 6 4 5 Removing the pump shaft 6 4 6 Fitting the pump shaft 6 4 7 Fitting the pump head and shaft seal 6 4 8 Fitting the impeller 7 4 9 Fitting...

Страница 2: ...l TM03 2218 3905 Pos Description Pos Description 1 Type designation 5 Country of origin 2 Product number serial number 6 Speed 3 Rated flow rate 7 Head 4 Max system pressure max liquid temperature 8 M...

Страница 3: ...uding plastic and rubber parts Code for materials including plastic and rubber parts As standard the pump has O rings of FKM rubber Code Description A Basic version Code Description F DIN flange Code...

Страница 4: ...orque Nm Lubricant 2 Pump head 1 Soapy water 6 Set screw 2 M8 15 Loctite 243 17 Air vent screw 1 8 20 Priming and drain plug 2 25 26 Staybolt 6 or 8 M10 45 36 Nut 6 or 8 M10 45 36a Nut 4 M8 M12 M16 12...

Страница 5: ...que tools A B C D E F G H Pos Designation For pos Description Part number A Pinch bar 2 6 Pos Designation For pos Description Part number B Ring open end spanner 17 20 36 36a 67 C Bit holder C D Bits...

Страница 6: ...e O ring pos 72a 4 3 Removing the impeller 1 Remove the pump head and motor See 4 2 Removing the pump head and motor 2 Remove the nut pos 67 holding the impeller pos 49 3 Remove the spring washer pos...

Страница 7: ...2a with soapy water and fit it on the pump head 2 Lift the motor with pump head by the pulley and carefully insert the impeller pos 49 into the pump housing pos 6 3 Fit the nuts pos 36 on the bolts po...

Страница 8: ...ngs of motors of 11 kW and up must be greased according to the indications on the motor nameplate The motor should be lubricated with a lithium based grease meeting the following specifications NLGI c...

Страница 9: ...pressure changes in the discharge pipe may damage the pump 3 Vent the pump during starting by loosening the air vent screw pos 17 in the pump head until a steady stream of liquid runs out of the vent...

Страница 10: ...casionally a The overload setting of motor protective circuit breaker is too low Set the motor protective circuit breaker cor rectly b Supply voltage periodically too low or too high Check the voltage...

Страница 11: ...tantly applies only to pumps with automatic start stop a The stop pressure has been set too high Reduce the selected stop pressure b Leakage in the discharge pipe Repair the leakage c The direction of...

Страница 12: ...12 13 8 Drawings 8 1 MTB 50 200 215 65 160 158 and 65 160 171 pump with feet TM03 4772 2706...

Страница 13: ...13 13 8 2 MTB 65 200 183 and 65 200 199 motor with feet TM03 4771 2706...