16
English (US)
10.2 Pump stop
The pump incorporates an electronic protective
function that will stop the pump in case of
•
dry running
•
overtemperature
•
overloaded motor
•
seized-up motor/pump.
The pump will restart automatically after 30 minutes
(for 24 hours) in case of any type of fault if the auto-
reset function is activated (the green indicator light
on the control panel is on, see point 5 in the table of
section
5
Auto-reset (green):
As standard, this function is activated on delivery (does not
apply to pump versions for Australia).
When the indicator light is
• on, the Auto-reset function is activated. The pump will
automatically attempt to restart every 30 minutes after an
alarm/fault over a period of 24 hours. After this period, the
pump will remain in the alarm condition.
• off, the Auto-reset function is deactivated. The pump will not
restart after an alarm/fault.
The Auto-reset function can be activated/deactivated by
pressing the on/off button for 5 seconds.
Note:
When water is consumed, the pump will start and stop
automatically, whether the Auto-reset light is on or off.
6
Alarm (red):
The indicator light is on when the pump is in alarm condition.
The alarm condition may have been caused by:
• dry running
• overtemperature
• overloaded motor
• seized-up motor/pump.
See section
.
Illustration
Description
Note
The pump settings are stored.
After supply failure, the pump will
automatically revert to its previous
operating condition when the
electricity supply is reconnected.
Содержание MQ 3-35
Страница 1: ...GRUNDFOS INSTRUCTIONS MQ Installation and operating instructions US C ...
Страница 2: ...2 ...
Страница 56: ...56 Appendix Appendix 1 Exploded view TM02 8410 4812 ...
Страница 58: ...58 ...