3. Installing the product
3.1 Location
Install the pump with accessibility for inspection and
maintenance. Allow ample space and headroom for
the use of an overhead crane or hoist sufficiently
strong to lift the unit.
Fig. 1
LS pump with accessibility for inspection
and headroom for the use of an
overhead crane
Install the pump as close as possible to the supply of
pumped liquid, so that the inlet pipe is as short and
direct as possible.
3.2 Mechanical installation
3.2.1 Lifting the product
Lift the pump by means of nylon straps and shackles.
Fig. 2
How to lift and handle the LS pumps
Fig. 3
How to lift and handle the LS bare shaft
pumps
3.2.2 Foundation
We recommend that you install the pump on a
concrete foundation, which is heavy enough to
provide permanent and rigid support for the entire
pump. The foundation must be capable of absorbing
any vibration, normal strain or shock. We
recommend that the weight of the concrete
foundation is 3 times the weight of the complete
pump unit. For specific requirements, consult the
contractor, engineer, or established industry
standards.
In installations where silent operation is particularly
important, we recommend a foundation that is up to
5 times as heavy as the complete pump unit.
TM
04
03
8
2
10
16
WARNING
Crushing hazard
Death or serious personal injury
- Make sure that all installations are
performed by persons experienced in
the placement, alignment and
connection of pumping equipment.
WARNING
Crushing hazard
Death or serious personal injury
- Handling must be performed by
qualified persons.
- When unloading the pump, lift equally at
four or more points on the base frame.
Do not lift by the motor or by the pump.