En
gl
is
h (
G
B)
20
*
Antimony, not approved for potable water.
The example shown is an LS 125-100-305F/273.1,
standard type with standard coupling, DIN PN 16
flange, cast iron pump casing with SS304 impeller,
BBQE mechanical shaft seal and clockwise direction
of rotation.
Code for pump casing and impeller materials
S: Cast iron and SS304
Q: Ductile iron and SS304
C: Cast iron and SS316
G: Ductile iron and SS316
B: Cast iron and bronze
A: Ductile iron and bronze
D: Cast iron and duplex stainless steel
H: Ductile iron and duplex stainless steel
U: SS304 and SS304
J: SS316 and SS316
K: Duplex stainless steel and duplex stainless steel
X: Special
Code for shaft seal or stuffing box
BAQE: Rubber bellows seal, unbalanced, carbon*/SiC, EPDM
BAQV: Rubber bellows seal, unbalanced, carbon*/SiC, FKM
AAQE: O-ring seal, unbalanced, carbon*/SiC, EPDM
AAQV: O-ring seal, unbalanced, carbon*/SiC, FKM
DAQE: O-ring seal, balanced, carbon*/SiC, EPDM
DAQV: O-ring seal, balanced, carbon*/SiC, FKM
SAQE: Rubber bellows seal, balanced, carbon*/SiC, EPDM
SAQV: Rubber bellows seal, balanced, carbon*/SiC, FKM
BBQE: Rubber bellows seal, unbalanced, carbon/SiC, EPDM
BBQV: Rubber bellows seal, unbalanced, carbon/SiC, FKM
ABQE: O-ring seal, unbalanced, carbon/SiC, EPDM
ABQV: O-ring seal, unbalanced, carbon/SiC, FKM
DBQE: O-ring seal, balanced, carbon/SiC, EPDM
DBQV: O-ring seal, balanced, carbon/SiC, FKM
SBQE: Rubber bellows seal, balanced, carbon/SiC, EPDM
SBQV: Rubber bellows seal, balanced, carbon/SiC, FKM
BQQE: Rubber bellows seal, unbalanced, SiC/SiC, EPDM
BQQV: Rubber bellows seal, unbalanced, SiC/SiC, FKM
AQQE: O-ring seal, unbalanced, SiC/SiC, EPDM
AQQV: O-ring seal, unbalanced, SiC/SiC, FKM
DQQE: O-ring seal, balanced, SiC/SiC, EPDM
DQQV: O-ring seal, balanced, SiC/SiC, FKM
SQQE: Rubber bellows seal, balanced, SiC/SiC, EPDM
SQQV: Rubber bellows seal, balanced, SiC/SiC, FKM
BBVP: Rubber bellows seal, carbon/aluminium oxide, nitrile rubber
SNEK: Stuffing box with synthetic polymer packing rings, uncooled, with internal barrier fluid
Direction of rotation
(Pump direction of rotation as seen from the motor end)
1:
Clockwise
2:
Counterclockwise
Example
LS 125 -100
-305X
/273.1 , (W) 1 F2 D S BBQE 1