P15.34

 

Threshold 
setting for 
switching to PV 
input

 

P15.33

400V 

If PV voltage is higher than the threshold, after the delay time of P15.24, it can 
be switched to PV input through relay output. In order to avoid repeated 
switching, the threshold needs to be higher than the threshold of P15.33. 
If the value is 0.0, the function is disabled.  
The default value depends on model. 

For models of 220V:  

0.75kW: 100.0V 
1.5kW, 2.2kW and 4kW: 120.0V 

For models of 380V: 

2.2kW

5.5kW: 240.0V 

 

Depend 

on model

 

 

P15.35 

Rated pump flow 

The pump flow is QN if the pump runs at the rated pump frequency and rated 
lift. Unit: cubic meter/hour. 

0.0 

 

P15.36 

Rated pump lift 

The pump lift is  HN  if the pump runs   at the rated frequency and rated 
current. Unit: meter 

0.0 

 

P15.37 

Voltage setting 
at PV 
undervoltage 
point 

When the PV voltage is less than the preset voltage, the system reports the PV 
undervoltage (UV) fault. 
The default value depends on the model. 
Setting range: 0.0

400.0 

Depend 

on model 

 

P17 Group:  Monitoring 

 

P17.38 

 
Current of the 
main winding 

Current of the main winding when applying the capacitance-removed mode to 
control the 1PH motor 
0.00

100.00A 

0.00A 

 

P17.39 

 
Current of the 
secondary 
winding 

Current of the secondary winding when applying the capacitance-removed 
mode to control the 1PH motor. 
0.00

100.00A 

0.00A 

 

P18 Group:  Parameters of Monitoring controller state

 

P18.00

 

PV reference 
voltage

 

MPPT is set at the controller side. This value is specified at the controller side. 

 

 

P18.01

 

Current PV 
voltage 

It is the PV input voltage provided by the boost module. 

 

 

P18.02

 

Bus voltage 
reference 

It is used to set the reference voltage of the bus when PV input is adopted.  
For models of 220V, the default value is 330.0V. 
and for models of 380V, the default value is 570.0V. 
Setting range: 220.0V

600.0V 

 

Depend 

on model

 

 

P18.07

 

PV input power 

Reserved. Unit: W 

 

 

P18.10 

Device 
configuration 
display 

 

0: PV power supply 
 1:  AC grid power supply 

 
 

 

 

P18.11

 

Current flow of 
pump 

Q=QN 

fN 

, unit: m

3

/h

 

0.0 

 

P18.12

 

Current lift of 
pump

 

 

H= 0.9H

N

*(

 

f

f

N

)

2

, unit: m

 

 

0.0

 

 

P18.13

 

MSB of pump 
total flow

 

Displaying the most significant 16 bits of the total flow of the pump. Unit: m

3

 

0

 

 

P18.14

 

LSB of pump 
total flow 

Displaying the least significant 16 bits of the total flow of the pump. Unit: m

3

 

Total flow of pump = P18.13 x 65535 + P18.14 

0.0

 

 

Содержание GI SPC 03 65 10

Страница 1: ...GRUNDFOS INSTRUCTION GI SPC Solar Pump Controller Electrical installation and operating instruction...

Страница 2: ......

Страница 3: ...terminals 10 5 4 4 Electrical wiring 10 AC input and output connections 10 DC input connections 10 Communication cable connections 11 6 Keypad Operation Procedure 12 6 1 Keypad introduction 12 6 2 Key...

Страница 4: ...uctions are not observed it may result in malfunction or damage to the equipment Notes or instructions that make the job easier and ensure safe operation Warning If these instructions are not observed...

Страница 5: ...cted either AC grid power or DC solar Power and the Output of the solar pump controller GI SPC is connected to the Submersible pump It is responsibility of the end user to provide the correct power su...

Страница 6: ...t mm Model H1 mm W1 mm D mm H2 mm W2 mm Installation hole GI SPC 03 65 10 280 300 137 131 195 8 Fig 4 Dimension for GI SPC 03 65 10 GI SPC 7 5 65 10 Unit mm Model H1 mm W1 mm D mm H2 mm W2 mm Installa...

Страница 7: ...nt Temperature C 60 60 Max Relative Humidity 95 95 Communication RS 485 Enclosure class IP65 4 2 1 Low Voltage Range 3 x 230 V Power KW Power HP Product Model Electrical Data Weight Kg Max P2 KW Rated...

Страница 8: ...onnector 1 1 AC connector 1 2 1 2 Keypad 1 1 Network cable 1 1 5 1 Installation Example Fig 5 Installation example showing the required clearance for mounting the product The environment temperature i...

Страница 9: ...circuit wiring The COM interfaces are the control circuit interfaces including one 485 communication channel and three digital input channels Figure 10 shows the wiring For interface definitions and s...

Страница 10: ...damage For models of choke consult Grundfos Connect the DC output AC input AC output and the communication wire to the males and then plug them to the females of the inverter Tighten up to ensure the...

Страница 11: ...in place is heard Tighten the nut in a opposite direction Fig 23 Connector assembly Communication cable connections Follow the below steps for the connecting communication cable Plug the cable into t...

Страница 12: ...LED OFF The pump controller is in the keypad operation state LED Blinking The pump controller is in the terminal s operation state LED ON The pump controller is in the remote communication control sta...

Страница 13: ...lected parameter from left to right 6 2 2 Running state parameter display After receiving a valid running command the pump controller enters the running state and the keypad displays the running state...

Страница 14: ...staying at the current function code Under the third level menu if the parameter is not blinking it means the function code cannot be modify The possible reasons could be This function code is not mod...

Страница 15: ...e multi function key QUICK JOG to FWD REVC shifting function P07 02 3 to change the running direction press RUN and STOP RST simultaneously in running state to make the pump controller to stop 1 LOCAL...

Страница 16: ...isabled 0 P00 18 Function restore parameter 0 No operation 1 Restore the default value 2 Clear fault records Note The function code will restore to 0 after finishing the operation of the selected func...

Страница 17: ...cy given channel set by P00 06 or the voltage given channel set by P04 27 to change the feature of the curve Note Vb in the below picture is the motor rated voltage and fb is the motor rated frequency...

Страница 18: ...V F frequency point 2 00 00Hz P04 06 V F voltage point 2 00 0 P04 07 V F frequency point 3 00 00Hz P04 08 V F voltage point 3 00 0 P04 09 V F slip compensation gain This function code is used to compe...

Страница 19: ...e 25 PID control pause 26 Traverse Pause stop at the current frequency 27 Traverse reset return to the center frequency 28 Counter reset 29 Torque control prohibition 30 ACC DEC prohibition 31 Counter...

Страница 20: ...o power frequency threshold or S input based Note Function 30 is relay output combining the functions 29 and 28 When one of the two conditions is met the relay output frequency is high 30 P06 04 Relay...

Страница 21: ...t tE 21 EEPROM operation fault EEP 22 PID feedback disconnection fault PIDE 23 Brake unit fault bCE 24 Running time arrival END 25 Electrical overload OL3 26 31 Reserved 32 Short to ground fault 1 ETH...

Страница 22: ...VMPP voltage reference 0 Voltage reference 1 Max powertracking 0 Apply voltage reference mode The reference is a fixed value and given by P15 02 1 Apply the reference voltage of Max power tracking The...

Страница 23: ...t is the reference of water level control analog signal For details see P15 12 and P12 13 0 P15 12 Water level threshold 0 0 100 0 This code is valid when P15 11 water level control is based on analog...

Страница 24: ...ported Otherwise it will be operated normally If the state is not continuous the delay counting will be cleared automatically 15 00 P15 21 Underload reset delay 0 0 1000 0s This parameter is used to s...

Страница 25: ...ly after the time set by P15 26 The medium value is the current bus voltage and the limit is P15 30 Maximum Minimum reference voltage Current bus voltge P15 30 and it will update to P15 26 and P15 27...

Страница 26: ...e main winding when applying the capacitance removed mode to control the 1PH motor 0 00 100 00A 0 00A P17 39 Current of the secondary winding Current of the secondary winding when applying the capacit...

Страница 27: ...flow of thepump is reset and P18 13 and P18 14 are reset to zero to re calculate the flow After the reset P18 15 is automatically modified to 0 0 P19 Group Voltage Boost P19 06 Bus voltage reference...

Страница 28: ...the setting of related function codes OC2 Overcurrent when deceleration OC3 Overcurrent when constant speed running UV Bus undervoltage 1 The voltage of the power supply is too low 2 The overvoltage s...

Страница 29: ...ne 2 Check the PID feedback source END Running time reached The actual running time of the pump controller is longer than the preset running time Contact grundfos to adjust the preset running time OL3...

Страница 30: ...If the water full alarm function is not enabled check whether there are terminal connections A tL Water empty alarm The water pumping tank is empty If the water empty alarm function is enabled the de...

Страница 31: ...2 Normal temperature 3 No abnormal noise Input and output parameters 1 Input voltage 2 Output current 1 Input voltage within limit 2 Output current under the rated value 1 Every 1000 running hours 2...

Страница 32: ...32 English GB...

Страница 33: ...Chaitra Complex Jayanagar 7th block West Bangalore 560 070 Telefax 080 26711101 Service Email serviceindia grundfos com HYDERABAD GRUNDFOS Pumps India Private Limited Shop No 8 9 2nd Floor Lumbini Jew...

Страница 34: ...grunfdos com The name Grundfos The Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos...

Отзывы: