Grundfos DWK O.10.80.37 Скачать руководство пользователя страница 14

En
gl

is

h (
G

B)

14

8. Servicing the product

The life of the product depends largely on the 
operating conditions, so we strongly recommend 
daily inspection and periodic servicing in order to 
guarantee maximum product lifetime.

8.1 Safety instructions and requirements

8.2 Service documentation

Service documentation is available on 
www.grundfos.com > International website > 
Grundfos Product Center > Service & support.
If you have any questions, please contact the 
nearest Grundfos company or service centre.

8.3 Contaminated products

The product will be classified as contaminated if it 
has been used for a liquid which is injurious to health 
or toxic.
If you request Grundfos to service the product, 
contact Grundfos with details about the pumped 
liquid before returning the product for service. 
Otherwise, Grundfos can refuse to accept the 
product for service.
Any application for service must include details 
about the pumped liquid.
Clean the product in the best possible way before 
you return it.
Costs of returning the product are to be paid by the 
customer.

8.4 Maintenance

Under normal operating conditions, remove the 
pump from the pit and inspect it once every year.
Under severe operating conditions where sand, 
fibrous material and solids are involved, do this once 
a month.
Check the following points:

Electrical test of the motor
See sections 

8.4.1 Checking the current and 

voltage

 and 

8.4.2 Checking the insulation 

resistance

.

Outlet pressure and flow rate
See section 

8.4.3 Checking the outlet pressure 

and flow rate

.

Seal-sensor resistance
See section 

8.4.4 Inspecting the seal sensor

.

Oil level and oil condition
See section 

8.4.5 Oil check and oil change

.

Impeller clearance
See section 

8.4.6 Inspection and adjustment of 

impeller clearance

.

8.4.1 Checking the current and voltage

Check the pump current and voltage. If the ammeter 
reading exceeds the rated value or is far lower than 
the rated value, there is a problem. The voltage must 
be stable within - 5 %/+ 5 % of the rated value 
throughout the operational period.

8.4.2 Checking the insulation resistance

If the insulation resistance has declined sharply 
since the previous reading, this is an indication of 
impending insulation failure, and the pump must be 
scheduled for service even though the insulation 
resistance may still be over 10 mega ohms.

WARNING

Electric shock

Death or serious personal injury
- Before starting any work on the product, 

make sure that the fuses have been 
removed or the main switch has been 
switched off and locked in position 0.
Make sure the power supply cannot be 
accidentally switched on.

WARNING

Crushing of hands

Death or serious personal injury
- Make sure that all rotating parts have 

stopped moving.

Maintenance and service must be carried 
out by specially trained persons.

WARNING

Biological hazard

Death or serious personal injury
- Flush the product thoroughly with clean 

water and rinse the product parts in 
water after dismantling.

The insulation resistance of the motor 
must be measured at least once a month.

The outlet pressure and flow rate must be 
measured at least once a month if a 
flowmeter is available.

Содержание DWK O.10.80.37

Страница 1: ...DWK Installation and operating instructions GRUNDFOS INSTRUCTIONS Installation and operating instructions DWK http net grundfos com qr i 97515233...

Страница 2: ...odes 8 4 2 Checking the direction of rotation 9 4 3 Preparing for startup 10 4 4 Startup 10 5 Handling and storing the product 10 5 1 Handling 10 5 2 Storing the product 10 6 Product introduction 11 6...

Страница 3: ...outside the pump pit Pits for submersible sewage and wastewater products contain sewage and wastewater with toxic and or disease causing substances Therefore all persons involved must wear appropriat...

Страница 4: ...must be rated for the purpose and checked for damage before any attempts are made to lift the product The lifting equipment rating must under no circumstances be exceeded CAUTION Crushing hazard Mino...

Страница 5: ...t of the pump outlet If a rigid pipe is used fit the union or coupling non return valve and isolating valve in the order mentioned when viewed from the pump If the pump is installed in muddy condition...

Страница 6: ...will cause a motor stop in case of high temperature in the motor The thermal switch must be connected to the control wire of the power cable inside the pump and to the safety circuit of the separate...

Страница 7: ...tar delta starting TM04 4096 0709 TM04 4097 3316 L1 L2 L3 MCCB V A MCCB MC Md My THR GU 01 GU 02 E U1 V1 W1 W2 U2 V2 1 M 3 T P T P S S S S S S F L MC T T My Md MC AUX THR THR MC OL RL GL AUX 6 5 GU01...

Страница 8: ...ication The actual effect cannot be predicted The acoustic noise level may increase See the installation and operating instructions for the frequency converter used for advice as to how to reduce the...

Страница 9: ...peration 4 2 Checking the direction of rotation Check the direction of rotation in the following way every time the pump is connected to a new installation Proceed as follows 1 Remove the pump from th...

Страница 10: ...e pump Store the pump in a vertical position on a pallet or a stand to keep the pump off the floor and facilitate easy removal Coil up the cable and seal the open end tightly with waterproof plastic a...

Страница 11: ...ded use 6 4 Approvals The standard version of the DWK pumps has been tested by T V according to EC Council Machinery Directive 2006 42 EC registration no AM 50143413 and report no 13009106 001 TM04 41...

Страница 12: ...t 5 50 Hz Frequency Hz 6 60 Hz 0D 380 415 V DOL Voltage and starting method 1D 380 415 V Y D 0E 220 240 V DOL 1E 220 240 V Y D Standard Pump version R Cast iron2 Z Custom built variant Customisation T...

Страница 13: ...witch which is optional is for high level alarm For further information see the installation and operating instructions for the pump controller selected 7 3 GU01 and GU02 GU01 is a monitoring device f...

Страница 14: ...rate See section 8 4 3 Checking the outlet pressure and flow rate Seal sensor resistance See section 8 4 4 Inspecting the seal sensor Oil level and oil condition See section 8 4 5 Oil check and oil ch...

Страница 15: ...ing hole pointing downwards in order to drain the pump of oil If the drained oil is contaminated or opaque this is an indication of an impending mechanical shaft seal failure Replace the mechanical se...

Страница 16: ...with the specifications on the pump nameplate 2 Increased current consumption due to large voltage drop Measure the voltage between two motor phases Tolerance 5 5 3 The impeller is blocked by impuriti...

Страница 17: ...liquid level 10 1 9 Max altitude above sea level 2000 m 10 2 Dimensions and weights 10 2 1 Dimensions See Dimensions and weights in the appendix 11 Disposing of the product This product or parts of i...

Страница 18: ...65 202 39 DWK O 6 50 15 Hose 468 235 110 50 215 428 492 65 202 41 Flange 468 276 110 50 215 428 520 65 202 41 DWK O 6 50 22 Hose 488 235 110 50 215 448 512 65 202 45 Flange 488 276 110 50 215 448 540...

Страница 19: ...09 179 100 333 734 872 116 302 110 DWK O 13 100 75 Hose 358 179 100 333 734 852 116 302 156 Flange 409 179 100 333 734 872 116 302 156 DWK O 13 100 110 Hose 358 179 100 333 779 897 116 302 190 Flange...

Страница 20: ...612 1318 1411 220 557 846 Flange 532 306 150 612 1318 1561 220 557 858 DWK E 10 150 550 Hose 532 306 150 612 1318 1411 220 557 909 Flange 532 306 150 612 1318 1561 220 557 921 DWK E 10 200 300 Hose 43...

Страница 21: ...0 530 DWK H 7 100 300 0 1161 1410 1180 470 100 580 DWK H 7 100 370 10 1350 1595 1445 518 100 800 DWK H 7 150 450 10 1350 1595 1445 518 150 830 DWK H 7 150 550 10 1350 1595 1445 518 150 850 DWK H 7 150...

Страница 22: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Страница 23: ...hona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa Grundf...

Страница 24: ...550 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...

Отзывы: