7. Protection and control functions
7.1 Built-in protection
The motor incorporates an electronic unit which
protects the motor in various situations.
In case of overload, the built-in overload protection
stops the pump for 5 minutes. After that period, the
pump is ready to restart if the starting conditions are
fulfilled.
To reset the pump, switch off the power supply for
one minute.
The motor is protected in the following situations:
•
dry running
•
voltage surges up to 6000 V
In areas with high lightning intensity, external
lightning protection is required.
•
overvoltage
•
undervoltage
•
overload
•
overtemperature
7.2 Thermal switches
All pumps have two sets of thermal switches
incorporated in the stator windings.
When a thermal switch is activated, the pump will
stop immediately, and it will not restart until the
motor windings have cooled sufficiently.
If the pump does not restart automatically, the pump
must be reset and restarted manually. If the pump
has to be restarted manually repeatedly, contact
Grundfos or a service workshop authorised by
Grundfos.
8. Servicing and maintaining the
product
8.1 Safety instructions and requirements
DANGER
Electric shock
Death or serious personal injury
- Before starting work on the pump, make
sure that the fuses have been removed
or the main switch has been switched
off.
- Make sure that the power supply cannot
be accidentally switched on.
CAUTION
Crushing of hands
Minor or moderate personal injury
- Do not put your hands or any tool into
the pump inlet or outlet port after the
pump has been connected to the power
supply, unless the pump has been
switched off by removing the fuses or
switching off the main switch.
- Make sure that all the rotating parts
have stopped moving.
CAUTION
Biological hazard
Minor or moderate personal injury
- Make sure to seal the pump outlet
properly when fitting the outlet pipe,
otherwise water might spray out of the
sealing.
CAUTION
Hot surface
Minor or moderate personal injury
- Do not touch the surface of the pump
while the pump is running.
WARNING
Crushing of hands
Death or serious personal injury
- When lifting the pump, make sure your
hand is not caught between the lifting
bracket and the hook.
Содержание DP AUTOADAPT Series
Страница 28: ...Appendix 28 Fig 4 Exploded view of DP 10 50 pump TM06 5879 0316...
Страница 29: ...Appendix 29 Fig 5 Exploded view of DP 10 65 pump TM06 5900 0316...
Страница 30: ...Appendix 30 Fig 6 Exploded view of EF 30 50 pump TM06 5913 0316...
Страница 46: ...Appendix 46 188a 188b 188c 189 190 193 193a 194 198 199 285 285a 285b 287 287a 287b 287c 532 Pos AR...
Страница 47: ...47...