17
The supply voltage and frequency are marked on the
pump nameplate. For voltage tolerance, see section
. Make sure that the motor is
suitable for the power supply available at the
installation site.
All pumps are supplied with 10 metres of cable and
a free cable end.
9.1 CIU unit (communication interface)
The Grundfos CIU unit (CIU = Communication
Interface Unit) is used as a communication interface
between a DP or EF pump and a main network.
The CIU unit is optional. See separate installation
and operating instructions supplied with the unit.
9.2 Electrical connection –
single-phase pumps
The pump has a patented start function which
eliminates the need of a starting capacitor. The
operating capacitor is incorporated in the pump.
Fig. 5
Wiring diagram for single-phase pumps
9.3 Electrical connection –
three-phase pumps
The pump motor is designed so that the phase
sequence in the electrical panel is clockwise (can be
determined with a phase sequence detector).
The pump does not start unless the phase sequence
is correct.
If the dry-running sensors are covered by liquid, and
the pump does not start, the cause may be a wrong
phase sequence. Interchange L1 and L2.
Fig. 6
Wiring diagram for three-phase pumps
9.4 Alarm relay/communication connection
The pump incorporates an alarm relay output.
NC and NO are available and can be used as
required, for example for acoustic or visual alarms.
Alternatively, the wires 4 and 6 can be used for
external communication via a CIU unit
(communication interface).
See example of wiring diagram in the documentation
supplied with the CIU unit.
Warning
Before installation and the first start-up
of the pump, check the cable for visible
defects to avoid short-circuits.
Warning
The pump must not run dry.
Caution
A possible replacement of the cable
must be carried out by Grundfos or
an authorised service workshop.
TM
0
4
4
297
1
209
2 A 230 VAC
2 A 230 VAC
TM
04
4
2
98
12
09
Note
If a CIU unit is connected, the relay
must not be used. The CIU unit
incorporates a relay which takes over
the alarm function.
2 A 230 VAC