English (GB)
18
10.4 Replacing the diaphragm
10.4.1 Switching off the pump
1. Switch off the pump and disconnect it from the power supply.
2. Depressurise the system.
3. Take suitable steps to ensure that the returning dosing
medium is safely collected.
10.4.2 Replacing the diaphragm
1. Loosen the six dosing head screws.
2. Remove the dosing head.
3. Unscrew the diaphragm by manually turning it
counter-clockwise.
4. Refit the retaining ring (4), shim ring (5), lip seal (7) and
supporting ring (6). Replace faulty parts.
5. Screw in the new diaphragm completely.
6. Remove the motor fan cover, and turn the fan blades until the
diaphragm reaches the bottom dead centre.
7. Refit the dosing head carefully, and cross-tighten the screws.
Maximum torque: 70-80 Nm.
8. Deaerate and start the dosing pump.
Fig. 19
Replacing the diaphragm
Grundfos gear oil
Alternative special oil for DHG 68
Note
If possible, rinse the dosing head, e.g. by supplying it
with water.
TM
03
7
189
45
0
6
Pos.
Components
1
Diaphragm
2
Dosing head screws
3
Dosing head
4
Retaining ring
5
Shim ring
6
Supporting ring
7
Lip seal
Caution
After initial start-up and after each time the
diaphragm is changed, tighten the dosing head
screws.
After approximately 6-10 operating hours or two
days, cross-tighten the dosing head screws using a
torque wrench.
Maximum torque: 70-80 Nm.
2
3
6
1
4
5
7
Order no
Description
98683958
5.0 l DHG 68
98683959
7.5 l DHG 68
Manufacturer
Designation
ARAL
Degol BMB 68
BP
BP-Energol GR-XP 68
Chevron
Chevron NL gear compound 68
ESSO
Spartan BP 68
Fina
Fina Giran 68
Mobil Oil
Mobilgear 626
Texaco
Texaco Meropa 68
Shell
Tellus 68
elf
reductelf SP 68