TM068598
Vertical lift of pumps with 10-30 HP (7.5 - 22
kW) Grundfos ML, MLE and MG, MGE motors
TM068599
Vertical lift of pumps with 7.5 - 250 HP (5.5 -
200 KW) motors of other makes than Grundfos
ML, MLE and MG, MGE motors
TM068162
Vertical lift of pumps without a motor
5. Mechanical installation
DANGER
Falling objects
Death or serious personal injury
‐
Fasten the pump securely to a solid
and even foundation according to
the specifications stated in the
installation and operating
instructions.
WARNING
Contamination when pumping
drinking water
Death or serious personal injury
‐
Before the pump is used for
supplying drinking water, flush the
pump thoroughly with clean water.
‐
Do not use the pump for drinking
water if the internal parts have
been in contact with particles or
substances not suitable for water
intended for human consumption.
WARNING
Falling objects
Death or serious personal injury
‐
Do not use the motor eyebolts to lift
the entire pump if the pump is fitted
with a motor of another make than
Grundfos ML, MLE and MG, MGE.
‐
Follow the lifting instructions.
‐
Use lifting equipment which is
approved for the weight of the
product.
‐
Persons must keep a safe distance
to the product during lifting
operations.
‐
Wear personal protective
equipment.
For lifting instructions, see the section on lifting
the product.
Related information
13
English (US)