3.4.1.1 Codes for motor
Code Description
P2 [HP (kW)]
C
0.33 (0.25)
D
0.5 (0.37)
E
0.75 (0.55)
F
1 (0.75)
G
1.5 (1.1)
H
2 (1.5)
I
3 (2.2)
K
5 (4)
L
7.5 (5.5)
M
10 (7.5)
N
15 (11)
O
20 (15)
P
25 (18.5)
Q
30 (22)
R
40 (30)
S
50 (37)
T
60 (45)
U
75 (55)
V
100 (75)
W
120 (90)
1
150 (110)
2
175 (132)
3
215 (160)
4
270 (200)
5
335 (250)
Phase and voltage (V)
A
1 x 200-240 V
B
3 x 200-240 V
C
3 x 440-480 V
D
3 x 380-500 V
X
Not defined
Speed variant (rpm)
A
1450-2000
B
2900-4000
C
4000-5900
2
2-pole
4
4-pole
4. Receiving the product
4.1 Transporting the product
WARNING
Falling objects
Death or serious personal injury
‐
Keep the product in a stable and
fixed position during transportation.
‐
Wear personal protective
equipment.
4.2 Unpacking the product
WARNING
Falling objects
Death or serious personal injury
‐
Keep the product in a stable
position during unpacking.
‐
Wear personal protective
equipment.
4.3 Inspecting the product
Before you install the product, do the following:
1. Check that the product is as ordered.
2. Check that no visible parts have been
damaged.
If parts are damaged or missing, contact your
local Grundfos sales company.
4.4 Lifting the product
WARNING
Falling objects
Death or serious personal injury
‐
Do not use the motor eyebolts to lift
the entire pump if the pump is fitted
with a motor of another make than
Grundfos ML, MLE and MG, MGE.
‐
Follow the lifting instructions.
‐
Use lifting equipment which is
approved for the weight of the
product.
‐
Persons must keep a safe distance
to the product during lifting
operations.
‐
Wear personal protective
equipment.
The following sections describe various lifting
situations and the lifting instructions which must
be followed in order to obtain safe lifting of the
product:
•
Position of lifting brackets: See the section on
position of lifting brackets.
9
English (US)