background image

Fault
 F

inding

8.

The pump 

performance is 
unstable.

a)

Pump inlet pressure too low.

b)

Suction pipe is partly blocked by 
impurities.

Remove and clean the suction pipe.

c)

Leakage in suction pipe.

d)

Air in suction pipe or pump.

Check the inlet conditions of the pump.

9.

The pump runs 
backwards when 
switched off.

a)

Leakage in suction pipe.

b)

Foot or non-return valve defective.

the valve.

c)

The foot valve is stuck in completely 

or partly open position.

Remove and clean, repair or replace 
the valve.

Self-priming pumps only:

10. The pump 

performance is 
unstable and the 
pump is noisy.

a)

The differential pressure across the 

pump is too low.

Close the tap gradually until the 
discharge pressure is stable and the 
noise has ceased.

11. When startup is 

attempted, the 
pump will start, but 
delivers no 
pressure or flow.

a)

Liquid column above non-return 

valve in discharge pipe prevents the 
pump from self-priming.

Empty the discharge pipe. Make sure 
that the non-return valve does not hold 
back liquid in the discharge pipe. 
Repeat the startup procedure.

b)

Suction pipe draws in air.

airtight from pump to liquid level. 
Repeat the startup procedure.

12. The pump runs, but 

does not deliver 
the rated flow.

a)

The internal valve did not close.

 

pressure or flow suddenly increases. 
Then open the tap gradually until the 
required flow is reached.

13. The pump 

performance is 
unstable.

a)

Pump inlet pressure too low.

b)

Suction pipe is partly blocked by 
impurities.

Remove and clean the suction pipe.

c)

Leakage in suction pipe.

d)

Air in suction pipe or pump.

Check the inlet conditions of the pump.

14. The pump runs 

backwards when 
switched off.

a)

Leakage in suction pipe.

b)

Foot or non-return valve defective.

the valve.

c)

The foot valve is stuck in completely 

or partly open position.

Remove and clean, repair or replace 
the valve.

Self-priming pumps only:

15. The pump 

performance is 
unstable and the 
pump is noisy.

a)

The differential pressure across the 

pump is too low. 

Close the tap gradually until the 
discharge pressure is stable and the 
noise has ceased.

16. When startup is 

attempted, the 
pump will start, but 
delivers no 
pressure or flow.

a)

Liquid column above non-return 

valve in discharge pipe prevents the 
pump from self-priming.

Empty the discharge pipe. Make sure 
that the non-return valve does not hold 
back liquid in the discharge pipe. 
Repeat the startup procedure.

b)

Suction pipe draws in air.

 

airtight from pump to liquid level. 
Repeat the startup procedure.

Fault

Cause

Remedy

Check the inlet conditions of the pump.

Remove and repair the suction pipe.

Vent the suction pipe/pump.

Remove and repair the suction pipe.

Remove and clean, repair or replace 

Make sure that the suction pipe is 

Close the tap gradually until the

Check the inlet conditions of the pump.

Remove and repair the suction pipe.

Vent the suction pipe/pump.

Remove and repair the suction pipe.

Remove and clean, repair or replace 

Make sure that the suction pipe is

4

Содержание CMSP-PM1

Страница 1: ...CMSP PM1 Installation and Operating Instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...t Note Notes or instructions that make the job easier and ensure safe operation 3 Mechanical installation Warning Before starting work on the CM Booster make sure that the power supply has been switch...

Страница 3: ...fective Repair or replace the PM unit 4 Frequent starts stops a Leakage in the pipework b Leaky non return valve c A valve close to the PM 1 outlet has been closed Open the valve 5 The pump does not s...

Страница 4: ...e a Pump inlet pressure too low b Suction pipe is partly blocked by impurities Remove and clean the suction pipe c Leakage in suction pipe d Air in suction pipe or pump Check the inlet conditions of t...

Страница 5: ...ste collection service 2 If this is not possible contact the nearest Grundfos company or service workshop Subject to alterations 17 The pump runs but does not deliver the rated flow a The internal val...

Страница 6: ...CMSP PM1 Pictorial Diagram 6...

Страница 7: ...CMSP PM1 Pictorial Diagram 7...

Страница 8: ...CMSP PM1 Pictorial Diagram 8...

Страница 9: ...CMSP PM1 Pictorial Diagram 9...

Страница 10: ...CMSP PM1 Pictorial Diagram 10...

Страница 11: ...CMSP PM1 Pictorial Diagram 11...

Страница 12: ...Subject to alterations CMSP PM1 0315 Cert No KLR 0402930 Website www grundfos com Toll Free No 1800 88 PUMP 7867...

Отзывы: