background image

3

Eng

lish (

U

S)

English (US) 

Installation and operating instructions

Original installation and operating instructions

CONTENTS

Page

1. Limited warranty

Products manufactured by GRUNDFOS PUMPS CORPORATION 
(Grundfos) are warranted to the original user only to be free of 
defects in material and workmanship for a period of 24 months 
from date of installation, but not more than 30 months from date 
of manufacture. Grundfos' liability under this warranty shall be 
limited to repairing or replacing at Grundfos' option, without 
charge, F.O.B. Grundfos' factory or authorized service station, 
any product of Grundfos' manufacture. Grundfos will not be liable 
for any costs of removal, installation, transportation, or any other 
charges which may arise in connection with a warranty claim. 
Products which are sold but not manufactured by Grundfos are 
subject to the warranty provided by the manufacturer of said 
products and not by Grundfos' warranty. Grundfos will not be
liable for damage or wear to products caused by abnormal
operating conditions, accident, abuse, misuse, unauthorized 
alteration or repair, or if the product was not installed in
accordance with Grundfos' printed installation and operating 
instructions.
To obtain service under this warranty, the defective product must 
be returned to the distributor or dealer of Grundfos' products from 
which it was purchased together with proof of purchase and 
installation date, failure date, and supporting installation data. 
Unless otherwise provided, the distributor or dealer will contact 
Grundfos or an authorized service station for instructions. Any 
defective product to be returned to Grundfos or a service station 
must be sent freight prepaid; documentation supporting the
warranty claim and/or a Return Material Authorization must be 
included if so instructed.
GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR 
CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES
ARISING FROM INSTALLATION, USE, OR ANY OTHER 
CAUSES. THERE ARE NO EXPRESS OR IMPLIED

WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND 
THOSE WARRANTIES DESCRIBED OR REFERRED TO 
ABOVE.
Some jurisdictions do not allow the exclusion or limitation of
incidental or consequential damages and some jurisdictions do 
not allow limit actions on how long implied warranties may last. 
Therefore, the above limitations or exclusions may not apply to 
you. This warranty gives you specific legal rights and you may 
also have other rights which vary from jurisdiction to jurisdiction.

2. Symbols used in this document

3. General

The Grundfos CME-Plus® system is for the pumping of clean, thin 
and non-explosive liquids, not containing solid particles or fibers 
that may attack the pump mechanically or chemically. 
This manual describes the installation and operation of the 
Grundfos CME-Plus® Kit Assembly.

Fig. 1

Tank and transducer manifold assembly

y.

4. Shipment inspection

Examine the components carefully to make sure no damage has 
occurred to the pump during shipment. Care should be taken to 
ensure the components are NOT dropped or mishandled.
Check to see that these parts are included; see fig. 8 on p. 5.
1. Tank and sensor manifold

– Diaphragm tank with O ring
– Pressure transducer
– 1/2" NPT plug
– 1/2" NPT cross fitting
– 1/2" to discharge size bushing
– 1/4" to 1/2" bushing
– 1/2" NPT nipple

1.

Limited warranty

3

2.

Symbols used in this document

3

3.

General

3

4.

Shipment inspection

3

5.

Kit assembly

4

5.2 Assemble the tank/transducer manifold

4

5.3 Attach the tank

5

6.

Install the pump

5

6.1 Set the pump parameters

5

6.2 Perform functional test

5

Warning

Prior to installation, read these installation and 
operating instructions. Installation and operation 
must comply with local regulations and accepted 
codes of good practice.

Warning

The use of this product requires experience with 
and knowledge of the product.
Persons with reduced physical, sensory or mental 
capabilities must not use this product, unless 
they are under supervision or have been 
instructed in the use of the product by a person 
responsible for their safety.
Children must not use or play with this product.

Warning

If these safety instructions are not observed, it 
may result in personal injury!

Caution

If these safety instructions are not observed, it 
may result in malfunction or damage to the 
equipment!

Note

Note

Notes or instructions that make the job easier 
and ensure safe operation.

T

M

05 0

651 1

31

1

Caution

If your pump is carrying the UL mark, official UL 
approval has been given for this pump for use 
with water only.

This product is Listed to applicable UL
standards and requirements by Underwriters 
Laboratories Inc. for use with water only.

CME Plus Kit Assembly I&O.book  Page 3  Thursday, April 7, 2011  4:41 PM

Содержание CME-Plus

Страница 1: ...GRUNDFOS INSTRUCTIONS CME Plus Kit assembly Installation and operating instructions ...

Страница 2: ...2 ...

Страница 3: ...ages and some jurisdictions do not allow limit actions on how long implied warranties may last Therefore the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction 2 Symbols used in this document 3 General The Grundfos CME Plus system is for the pumping of clean thin and non ...

Страница 4: ... four ports of the cross fitting See fig 3 Fig 3 Threading plug into cross fitting 3 Thread the 1 4 to 1 2 NPT bushing into one of the ports next to the plug from Step 2 in the cross fitting This will be opposite of where the tank will be positioned See fig 4 Tighten until wrench tight Fig 4 Threading bushing into cross fitting next to plug 4 Thread the pressure transducer into the 1 4 NPT port of...

Страница 5: ...bar or 0 145 psi 0 10 bar STOP FUNCTION Active CONTROL MODE Controlled 6 2 Perform functional test Start the pump and perform the following functional test including monitoring for leaks and watching for any obvious problems 1 Reduce the setpoint to the second LED light from the bottom on the motor control panel by pressing the DOWN arrow as many times as necessary 2 Slowly close the discharge lin...

Страница 6: ...6 ...

Страница 7: ...27 3400 Telefax 1 913 227 3500 Canada GRUNDFOS Canada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Phone 1 905 829 9533 Telefax 1 905 829 9512 México Bombas GRUNDFOS de México S A de C V Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto Apodaca N L C P 66600 Phone 52 81 8144 4000 Telefax 52 81 8144 4010 ...

Страница 8: ...akes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denmark All rights reserved worldwide L CM TL 004 0411 US 2011 Grundfos Pumps Corp ...

Отзывы: