background image

GRUNDFOS 

INSTRUCTIONS

Hydro Dome

Installation and operating instructions

Содержание CHV 2-100

Страница 1: ...GRUNDFOS INSTRUCTIONS Hydro Dome Installation and operating instructions ...

Страница 2: ......

Страница 3: ...ice d installation et de fonctionnement 51 Hrvatski HR Montažne i pogonske upute 58 Italiano IT Istruzioni di installazione e funzionamento 66 Nederlands NL Installatie en bedieningsinstructies 73 Polski PL Instrukcja montażu i eksploatacji 80 Português PT Instruções de instalação e funcionamento 88 Русский RU Руководство по монтажу и эксплуатации 95 Slovenčina SK Návod na montáž a prevádzku 104 S...

Страница 4: ...02 Directiva EMC 2004 108 CE Normas aplicadas EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 y EN 61000 6 4 2007 FR Déclaration de Conformité Nous Grundfos déclarons sous notre seule responsabilité que les produits Hydro Dome auxquels se réfère cette déclaration sont conformes aux Directives du Conseil concernant le rapprochement des législations des Etats membres CE relatives aux normes én...

Страница 5: ... i EN 61000 6 4 2007 FI Vaatimustenmukaisuusvakuutus Me Grundfos vakuutamme omalla vastuullamme että tuotteet Hydro Dome joita tämä vakuutus koskee ovat EY n jäsenvaltioiden lainsäädännön yhdenmukaistamiseen tähtäävien Euroopan neuvoston direktiivien vaatimusten mukaisia seuraavasti Konedirektiivi 2006 42 EY Sovellettavat standardit EN 809 1998 ja EN 60204 1 2006 Pienjännitedirektiivi 2006 95 EY S...

Страница 6: ... the consumption is still falling the last pump will finally fill the tank and then stop 1 Symbols used in this document 6 2 General 6 2 1 Applications 6 2 2 Operating conditions 6 3 Product description 6 4 Operation and functions 6 4 1 Single phase versions 7 4 2 Three phase versions 7 5 Installation 8 5 1 Location 8 5 2 Foundation 8 5 3 Pipework 8 5 4 Dry running protection 8 5 5 Overpressure pr...

Страница 7: ...it breaker Dry running protection by means of an additional pressure switch or level switch accessory See section 5 4 Overpressure protection by means of an additional pressure switch accessory See section 5 5 Figure 2 shows the control panel of the CS 203b controller Fig 2 Key to the symbols in fig 2 CS 201 control panel TM01 7877 4999 Pos Description 1 Main switch 2 Selector switch for each pump...

Страница 8: ...on When the maximum pressure is reached the pumps will be cut out and the alarm is activated When the correct pressure is restored the pumps are cut in automatically The alarm must be reset manually 5 6 Tank selection To ensure reliable operation the booster set must be connected to a diaphragm tank or bladder tank The tank volume can be optimised according to the pumping condition Furthermore the...

Страница 9: ...ig 5 Fig 5 1 Pressure switch Pr 1 2 Pressure switch Pr 2 The pressure switches are factory set to a zero bar inlet pressure See the following table Recommended tank precharge pressure when using the factory settings Check that this pressure does not exceed the maximum tank precharge pressure The setting can be changed according to the hydraulic conditions of the pumping system e g when the booster...

Страница 10: ...esired levels pos 1 fig 6 10 3 Open the drain valve pos 8 fig 7 until both pumps start Close the drain valve When the new maximum pressure is reached the pumps will stop automatically 10 4 Repeat from point 10 2 until the desired cut out pressures are obtained 11 Cut in pressure settings 11 1 Start the pumps in automatic operation When the maximum pressure Pr 1 is reached the pumps will stop autom...

Страница 11: ...r Start stop frequency Maximum 100 per hour Liquid temperature and operating pressure may be limited by the diaphragm tank or bladder tank For further technical details see installation and operating instructions for CHV pumps CS 201 controller Enclosure class IP54 Insulation Double insulated cabinet The controller must not be exposed to direct sunlight Fuses 8 A aM 10 3 x 38 mm 5 x 20 100 mA Tran...

Страница 12: ...ing of pressure switch Increase the cut out pressure and or differential pressure Δp b Tank defective Repair the tank 4 Pump is running but delivers no water a Suction pipe pump or discharge pipe blocked by impurities Clean the suction pipe pump or discharge pipe b Non return valve blocked in closed position Clean the non return valve c Suction pipe leaky Repair the suction pipe d Pump suction pip...

Страница 13: ...S Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 370 52 395 431 Malaysia GRUNDFOS Pumps Sdn B...